Skip to content

An improper check for unusual or exceptional conditions...

Moderate severity Unreviewed Published May 24, 2022 to the GitHub Advisory Database • Updated Jan 29, 2023

Package

No package listedSuggest a package

Affected versions

Unknown

Patched versions

Unknown

Description

An improper check for unusual or exceptional conditions vulnerability in Juniper Networks MX Series platforms with Trio-based MPC (Modular Port Concentrator) deployed in (Ethernet VPN) EVPN-(Virtual Extensible LAN) VXLAN configuration, may allow an attacker sending specific Layer 2 traffic to cause Distributed Denial of Service (DDoS) protection to trigger unexpectedly, resulting in traffic impact. Continued receipt and processing of this specific Layer 2 frames will sustain the Denial of Service (DoS) condition. An indication of compromise is to check DDOS LACP violations: user@device> show ddos-protection protocols statistics brief | match lacp This issue only affects the MX Series platforms with Trio-based MPC. No other products or platforms are affected. This issue affects: Juniper Networks Junos OS on MX Series: 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R3-S4; 18.1 versions prior to 18.1R3-S12; 18.2 versions prior to 18.2R2-S8, 18.2R3-S8; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R1-S8, 18.4R2-S7, 18.4R3-S7; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S6; 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R2, 20.1R3; 20.2 versions prior to 20.2R2-S1, 20.2R3; 20.3 versions prior to 20.3R1-S1, 20.3R2;

References

Published by the National Vulnerability Database Apr 22, 2021
Published to the GitHub Advisory Database May 24, 2022
Last updated Jan 29, 2023

Severity

Moderate

EPSS score

Exploit Prediction Scoring System (EPSS)

This score estimates the probability of this vulnerability being exploited within the next 30 days. Data provided by FIRST.
(25th percentile)

Weaknesses

Improper Check for Unusual or Exceptional Conditions

The product does not check or incorrectly checks for unusual or exceptional conditions that are not expected to occur frequently during day to day operation of the product. Learn more on MITRE.

CVE ID

CVE-2021-0228

GHSA ID

GHSA-389v-3v24-gh3w

Source code

No known source code

Dependabot alerts are not supported on this advisory because it does not have a package from a supported ecosystem with an affected and fixed version.

Learn more about GitHub language support

Loading Checking history
See something to contribute? Suggest improvements for this vulnerability.