Battery
- DO NOT plug/unplug battery while either power switch is in the on position.
- DO NOT attempt to power the robot with a discharged battery.
- DO NOT leave battery plugged into robot overnight or when not in use to prevent over accidental over discharge.
| LED Pattern | Meaning |
|---|---|
| Red/Green Flashing | BMS Connected; Battery Terminals Disconnected |
| Quick Red Flashing | Charge Cycle Beginning |
| Solid Red | Constant Current (SoC < 85%) |
| Red Flashing | Constant Voltage (SoC > 85%) |
| Solid Yellow | Equalize Stage |
| Solid Green | Charge Cycle Done/No Battery Connected |
- When disconnecting the battery from the charger, ALWAYS disconnect the data cable first then the power cable.
- DO NOT unplug the power cable if charger indicator is not green.
- DO NOT use any charger other than the one provided with Cassie.
- DO charge in an open and well ventilated area away from bystanders.
Battery damage includes, but is not limited to:
- Short circuit
- Drop, crush, shock, vibration, or piercing
- Temperature in excess of 60 C°
- Exposure to fire or submersion in water
If a battery begins venting or catches on fire, evacuate the area and call the fire department.
Battery fires can be extinguished using a class C extinguisher. DO NOT use a Class D extinguisher as these are meant to extinguish Lithium metal fires and will not be effective.
In order to prolong your battery life, please refer to the following tips.
- Depth of discharge is an important factor in the cycle life of your battery. Repeated deep cycles to 0% will negatively impact the lifetime of your pack, as will repeated shallow cycles to above 90%.
- Storing your batteries at or below room temperature will limit self discharge and increase cycle life.
- Your battery will lose charge per day from powering the battery management circuitry, so exercise caution storing batteries for extended periods. A fully discharged battery that is stored for more than a few days, or a fully charged battery stored for long periods may be unrecoverable. Battery revisions have improved the self-discharge according to the list below. The battery status checker script will indicate if the pack is first or second generation (make sure to download the newest version here). The generation can also be determined from the serialized sticker affixed to the pack.
- First generation pack (S/N AL-1383-x): ~4% per day, ~25 days to fully discharge
- Second generation pack (S/N AL-1417-x): ~1.3% per day, ~75 days to fully discharge
- Leaving the battery plugged into the charger will not keep the battery "topped off." To charge the battery, it must be unplugged and plugged back into the charger.
- Batteries should be unplugged from the charger when fully charged. Because of leakage current through the charger, self-discharge will increase while it remains plugged in and "shelf-life" will significantly decrease.
We recommend as best practice to have a sign out sheet for each battery you have where the state of charge and date is recorded each time a battery is used. Then when a battery is discharged below 50% it is placed on the charger, and when it has been longer than a week or so since it was used, the battery charge is checked and charged accordingly. Below are links to example policies and sign out sheets.
There is a chance that Electrostatic Discharge (ESD) will damage the PCB inside the battery. To reduce the risk of damage to your pack, take the following precautions when handling your battery:
- Before handling the battery, ground yourself by touching a large metal object, such as a desk, metal door frame, or the metal chassis of a device that is plugged into the wall.
- When plugging the battery into the robot or charger, always plug in the large 48V power connector first, and the small data cable second. This allows the ground levels to equalize before connecting sensitive components
- Introduction
- Limitation of Liability
- Warning Symbols in this Manual
- General Precautions
- Mechanical Precautions
- Maintenance Precautions
- Research and Development Precautions
- Battery Safety
- Mechanical Overview
- Electrical Overview