Run e2e Tests #715
run-e2e-tests.yml
on: workflow_dispatch
Matrix: run-e2e-tests-on-utils
Annotations
12 errors
run-e2e-tests-on-utils (packages/tracer, 22, x86_64)
Process completed with exit code 1.
|
tests/e2e/middy.test.ts > Tracer E2E tests, middy instrumentation:
packages/testing/lib/esm/xray-traces-utils.js#L145
Error: Failed to get trace details after 20 retries
❯ ../testing/lib/esm/xray-traces-utils.js:145:19
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/middy.test.ts:69:17
Caused by: Caused by: Error: Expected 4 segments, got 5 for traceId 1-68dd297d-796f379e78dfefff7d797ad9
❯ parseAndSortTrace ../testing/lib/esm/xray-traces-utils.js:88:15
❯ getTraceDetails ../testing/lib/esm/xray-traces-utils.js:129:36
❯ ../testing/lib/esm/xray-traces-utils.js:140:16
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/middy.test.ts:69:17
|
tests/e2e/decorator.test.ts > Tracer E2E tests, decorator instrumentation:
packages/testing/lib/esm/xray-traces-utils.js#L145
Error: Failed to get trace details after 20 retries
❯ ../testing/lib/esm/xray-traces-utils.js:145:19
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/decorator.test.ts:70:17
Caused by: Caused by: Error: Expected 4 segments, got 2 for traceId 1-68dd2984-67bfd43c7821881f3702ac4a
❯ parseAndSortTrace ../testing/lib/esm/xray-traces-utils.js:88:15
❯ getTraceDetails ../testing/lib/esm/xray-traces-utils.js:129:36
❯ ../testing/lib/esm/xray-traces-utils.js:140:16
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/decorator.test.ts:70:17
|
run-e2e-tests-on-utils (packages/tracer, 20, arm64)
Process completed with exit code 1.
|
tests/e2e/middy.test.ts > Tracer E2E tests, middy instrumentation:
packages/testing/lib/esm/xray-traces-utils.js#L145
Error: Failed to get trace details after 20 retries
❯ ../testing/lib/esm/xray-traces-utils.js:145:19
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/middy.test.ts:69:17
Caused by: Caused by: Error: Expected 4 segments, got 5 for traceId 1-68dd29a2-7f8e341e3419b7ab75b25255
❯ parseAndSortTrace ../testing/lib/esm/xray-traces-utils.js:88:15
❯ getTraceDetails ../testing/lib/esm/xray-traces-utils.js:129:36
❯ ../testing/lib/esm/xray-traces-utils.js:140:16
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/middy.test.ts:69:17
|
tests/e2e/decorator.test.ts > Tracer E2E tests, decorator instrumentation:
packages/testing/lib/esm/xray-traces-utils.js#L145
Error: Failed to get trace details after 20 retries
❯ ../testing/lib/esm/xray-traces-utils.js:145:19
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/decorator.test.ts:70:17
Caused by: Caused by: Error: Expected 4 segments, got 2 for traceId 1-68dd29aa-7df6ea8d7e41236c6304fbe5
❯ parseAndSortTrace ../testing/lib/esm/xray-traces-utils.js:88:15
❯ getTraceDetails ../testing/lib/esm/xray-traces-utils.js:129:36
❯ ../testing/lib/esm/xray-traces-utils.js:140:16
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/decorator.test.ts:70:17
|
run-e2e-tests-on-utils (packages/tracer, 22, arm64)
Process completed with exit code 1.
|
tests/e2e/middy.test.ts > Tracer E2E tests, middy instrumentation:
packages/testing/lib/esm/xray-traces-utils.js#L145
Error: Failed to get trace details after 20 retries
❯ ../testing/lib/esm/xray-traces-utils.js:145:19
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/middy.test.ts:69:17
Caused by: Caused by: Error: Expected 4 segments, got 5 for traceId 1-68dd298b-74c4cc7819e0520e6e05164e
❯ parseAndSortTrace ../testing/lib/esm/xray-traces-utils.js:88:15
❯ getTraceDetails ../testing/lib/esm/xray-traces-utils.js:129:36
❯ ../testing/lib/esm/xray-traces-utils.js:140:16
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/middy.test.ts:69:17
|
tests/e2e/decorator.test.ts > Tracer E2E tests, decorator instrumentation:
packages/testing/lib/esm/xray-traces-utils.js#L145
Error: Failed to get trace details after 20 retries
❯ ../testing/lib/esm/xray-traces-utils.js:145:19
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/decorator.test.ts:70:17
Caused by: Caused by: Error: Expected 4 segments, got 2 for traceId 1-68dd29e1-1d5c641a6a12f4206576593c
❯ parseAndSortTrace ../testing/lib/esm/xray-traces-utils.js:88:15
❯ getTraceDetails ../testing/lib/esm/xray-traces-utils.js:129:36
❯ ../testing/lib/esm/xray-traces-utils.js:140:16
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/decorator.test.ts:70:17
|
run-e2e-tests-on-utils (packages/tracer, 20, x86_64)
Process completed with exit code 1.
|
tests/e2e/middy.test.ts > Tracer E2E tests, middy instrumentation:
packages/testing/lib/esm/xray-traces-utils.js#L145
Error: Failed to get trace details after 20 retries
❯ ../testing/lib/esm/xray-traces-utils.js:145:19
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/middy.test.ts:69:17
Caused by: Caused by: Error: Expected 4 segments, got 5 for traceId 1-68dd2993-4148718248f3985f001ad3b1
❯ parseAndSortTrace ../testing/lib/esm/xray-traces-utils.js:88:15
❯ getTraceDetails ../testing/lib/esm/xray-traces-utils.js:129:36
❯ ../testing/lib/esm/xray-traces-utils.js:140:16
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/middy.test.ts:69:17
|
tests/e2e/decorator.test.ts > Tracer E2E tests, decorator instrumentation:
packages/testing/lib/esm/xray-traces-utils.js#L145
Error: Failed to get trace details after 20 retries
❯ ../testing/lib/esm/xray-traces-utils.js:145:19
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/decorator.test.ts:70:17
Caused by: Caused by: Error: Expected 4 segments, got 2 for traceId 1-68dd29eb-22269a2049f3d90f21fd3115
❯ parseAndSortTrace ../testing/lib/esm/xray-traces-utils.js:88:15
❯ getTraceDetails ../testing/lib/esm/xray-traces-utils.js:129:36
❯ ../testing/lib/esm/xray-traces-utils.js:140:16
❯ getXRayTraceData ../testing/lib/esm/xray-traces-utils.js:194:20
❯ getTraces ../testing/lib/esm/xray-traces-utils.js:210:20
❯ tests/e2e/decorator.test.ts:70:17
|