Skip to content

Added ABB EV3 modbus meter#329

Open
jimfranssen wants to merge 5 commits intodingo35:masterfrom
jimfranssen:master
Open

Added ABB EV3 modbus meter#329
jimfranssen wants to merge 5 commits intodingo35:masterfrom
jimfranssen:master

Conversation

@jimfranssen
Copy link

Added code to implement out of the box solution for ABB EV3 energy meter.
When EV meter timeout is triggered for the ABB EV3 then SmartEVSE will automatically change the factory parity of the ABB EV3 from even to none. This is done by temporarily changing SmartEVSE UART parity and writing to the parity register of the ABB EV3. After that the meter works correctly. Solution has been fully tested. ABB EV3 uses only numeric hex decimal addresses (note of this has been added to meter struct).

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.