Skip to content

Conversation

@jmduarte
Copy link
Member

@jmduarte jmduarte commented Apr 9, 2023

Add zcu104 board to the VivadoAccelerator backend. Note, it would be nice to add a test that actually generates a bitfile (not just synthesis)

Type of change

  • New feature (non-breaking change which adds functionality)

Tests

https://gist.github.com/jmduarte/41a6afcd412dbd7c39cdbd0e2a1a01a3

Checklist

  • I have read the guidelines for contributing.
  • I have commented my code, particularly in hard-to-understand areas.
  • I have made corresponding changes to the documentation.
  • My changes generate no new warnings.
  • I have installed and run pre-commit on the files I edited or added.
  • I have added tests that prove my fix is effective or that my feature works.

@jmduarte jmduarte requested a review from nghielme April 9, 2023 04:45
@jmduarte
Copy link
Member Author

jmduarte commented Apr 9, 2023

Note I see some warnings when generating the bitfile that may need to be addressed:

WARNING: [xilinx.com:ip:zynq_ultra_ps_e:3.3-1] /zynq_ultra_ps_e_0</axi_smc/M00_AXI> of </axi_smc> is connected to </zynq_ultra_ps_e_0>. To avoid loops, any interface from </zynq_ultra_ps_e_0> should not be connected to </zynq_ultra_ps_e_0> using </axi_smc>
WARNING: [BD 41-237] Bus Interface property AWUSER_WIDTH does not match between /ps8_0_axi_periph/s00_couplers/auto_ds/S_AXI(0) and /zynq_ultra_ps_e_0/M_AXI_HPM0_FPD(16)
WARNING: [BD 41-237] Bus Interface property ARUSER_WIDTH does not match between /ps8_0_axi_periph/s00_couplers/auto_ds/S_AXI(0) and /zynq_ultra_ps_e_0/M_AXI_HPM0_FPD(16)
WARNING: [BD 41-237] Bus Interface property AWUSER_WIDTH does not match between /ps8_0_axi_periph/s01_couplers/auto_ds/S_AXI(0) and /zynq_ultra_ps_e_0/M_AXI_HPM1_FPD(16)
WARNING: [BD 41-237] Bus Interface property ARUSER_WIDTH does not match between /ps8_0_axi_periph/s01_couplers/auto_ds/S_AXI(0) and /zynq_ultra_ps_e_0/M_AXI_HPM1_FPD(16)
WARNING: [BD 41-237] Bus Interface property AWUSER_WIDTH does not match between /zynq_ultra_ps_e_0/S_AXI_HPC0_FPD(1) and /axi_smc/M00_AXI(0)
WARNING: [BD 41-237] Bus Interface property ARUSER_WIDTH does not match between /zynq_ultra_ps_e_0/S_AXI_HPC0_FPD(1) and /axi_smc/M00_AXI(0)
WARNING: [IP_Flow 19-5611] Unable to find an associated reset port for the interface 'M_AXI_HPM0_FPD'. A default connection has been created.
WARNING: [IP_Flow 19-5611] Unable to find an associated reset port for the interface 'M_AXI_HPM1_FPD'. A default connection has been created.
WARNING: [IP_Flow 19-5611] Unable to find an associated reset port for the interface 'S_AXI_HPC0_FPD'. A default connection has been created.
WARNING: [IP_Flow 19-4994] Overwriting existing constraint file '/home/users/woodson/issue_740/model_pynq/hls4ml_prj_zcu104/myproject_vivado_accelerator/project_1.srcs/sources_1/bd/design_1/ip/design_1_auto_ds_0/design_1_auto_ds_0_ooc.xdc'
WARNING: [IP_Flow 19-5611] Unable to find an associated reset port for the interface 'S_AXI'. A default connection has been created.
WARNING: [IP_Flow 19-5611] Unable to find an associated reset port for the interface 'M_AXI'. A default connection has been created.
WARNING: [IP_Flow 19-4994] Overwriting existing constraint file '/home/users/woodson/issue_740/model_pynq/hls4ml_prj_zcu104/myproject_vivado_accelerator/project_1.srcs/sources_1/bd/design_1/ip/design_1_auto_pc_0/design_1_auto_pc_0_ooc.xdc'
WARNING: [IP_Flow 19-4994] Overwriting existing constraint file '/home/users/woodson/issue_740/model_pynq/hls4ml_prj_zcu104/myproject_vivado_accelerator/project_1.srcs/sources_1/bd/design_1/ip/design_1_auto_ds_1/design_1_auto_ds_1_ooc.xdc'
WARNING: [IP_Flow 19-5611] Unable to find an associated reset port for the interface 'S_AXI'. A default connection has been created.
WARNING: [IP_Flow 19-5611] Unable to find an associated reset port for the interface 'M_AXI'. A default connection has been created.
WARNING: [IP_Flow 19-4994] Overwriting existing constraint file '/home/users/woodson/issue_740/model_pynq/hls4ml_prj_zcu104/myproject_vivado_accelerator/project_1.srcs/sources_1/bd/design_1/ip/design_1_auto_pc_1/design_1_auto_pc_1_ooc.xdc'
WARNING: [IP_Flow 19-519] IP 'design_1_myproject_axi_0_0' detected a language mismatch between 'VHDL Simulation Wrapper' and 'Verilog Simulation' output products. Please check with the IP provider to see if this is expected.

@jmduarte jmduarte added this to the v0.8.0 milestone Apr 10, 2023
@jmduarte jmduarte removed this from the v0.8.0 milestone Oct 20, 2023
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Projects

None yet

Development

Successfully merging this pull request may close these issues.

2 participants