4 changes: 4 additions & 0 deletions RELEASE_NOTES.md
Original file line number Diff line number Diff line change
Expand Up @@ -41,6 +41,10 @@
- Rename `SensorStateCode.SENSOR_STATE_CODE_ON` to `SensorStateCode.SENSOR_STATE_CODE_OK`, to better indicate that we do not control on/off state of sensors.
- Rename `ComponentData` to `ElectricalComponentTelemetry` to better specify its purpose of encapsulating general telemetry data from electrical components.
- Rename `SensorData` to `SensorTelemetry` to better specify its purpose of encapsulating general telemetry data from sensors.
- The following changes have been made to the `ElectricalComponentDiagnosticCode` enum (previously `ComponentErrorCode`):
- The code `UNDERVOLTAGE_SHUTDOWN` has been removed in favour of `UNDERVOLTAGE`.
- New diagnostic codes have been added to cover more cases, especially for inverters.
- The codes have been renumbered.

## Bug Fixes

Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -264,50 +264,97 @@ enum ElectricalComponentDiagnosticCode {
// sanity checks to fail.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_PLAUSIBILITY_ERROR = 13;

// There is or was a system shutdown due to undervoltage.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_UNDERVOLTAGE_SHUTDOWN = 14;

// There is an unexpected pilot failure in an electric vehicle (EV) component.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_UNEXPECTED_PILOT_FAILURE = 15;

// A fault current has been detected in the component.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_FAULT_CURRENT = 16;
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_FAULT_CURRENT = 14;

// A short circuit has been detected in the component.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_SHORT_CIRCUIT = 17;
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_SHORT_CIRCUIT = 15;

// The component has been configured incorrectly.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_CONFIG_ERROR = 18;
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_CONFIG_ERROR = 16;

// A illegal state has been requested for the component.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_ILLEGAL_COMPONENT_STATE_CODE_REQUESTED
= 19;
= 17;

// The hardware of the component is inaccessible.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_HARDWARE_INACCESSIBLE = 20;
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_HARDWARE_INACCESSIBLE = 18;

// There is an internal error within the component.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_INTERNAL = 21;
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_INTERNAL = 19;

// The component is unauthorized to perform the last requested action.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_UNAUTHORIZED = 22;
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_UNAUTHORIZED = 20;

// There is excessive leakage current in the component.
// The threshold for excessive leakage current is defined by the component
// manufacturer.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EXCESS_LEAKAGE_CURRENT = 21;

// The component is inoperable due to the insulation resistance being too low.
// The threshold for low insulation resistance is defined by the component
// manufacturer, or can be configured by the user in the component.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_LOW_SYSTEM_INSULATION_RESISTANCE = 22;

// The component is inoperable due to the faulty grounding.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_GROUND_FAULT = 23;

// The component is inoperable due to arcing.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_ARC_FAULT = 24;

// The component is inoperable due to its fan being faulty.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_FAN_FAULT = 25;

// The component is inoperable due to the component's hardware being faulty.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_HARDWARE_FAULT = 26;

// The component is inoperable due to its hardware being faulty.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_PROTECTIVE_SHUTDOWN = 27;

// The component is inoperable due to the grid voltage being too high.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_GRID_OVERVOLTAGE = 30;

// The component is inoperable due to the grid voltage being too low.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_GRID_UNDERVOLTAGE = 31;

// The component is inoperable due to the grid frequency being too high.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_GRID_OVERFREQUENCY = 32;

// The component is inoperable due to the grid frequency being too low.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_GRID_UNDERFREQUENCY = 33;

// The component is inoperable due to the grid being disconnected, despite
// the AC relay being closed.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_GRID_DISCONNECTED = 34;

// The component is inoperable due to the grid voltage being imbalanced.
// This happens when the voltage of one or more phases is outside the
// acceptable range.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_GRID_VOLTAGE_IMBALANCE = 35;

// The component is inoperable due to the grid being in a non-standard
// configuration.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_GRID_ABNORMAL = 36;

// There is an unexpected pilot failure in an electric vehicle (EV) component.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_UNEXPECTED_PILOT_FAILURE = 40;

// The electric vehicle (EV) cable was abruptly unplugged from the charging
// station.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_CHARGING_CABLE_UNPLUGGED_FROM_STATION
= 40;
= 41;

// The electric vehicle (EV) cable was abruptly unplugged from the vehicle.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_CHARGING_CABLE_UNPLUGGED_FROM_EV = 41;
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_CHARGING_CABLE_UNPLUGGED_FROM_EV = 42;

// There is a cable lock failure with the electric vehicle (EV).
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_CHARGING_CABLE_LOCK_FAILED = 42;
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_CHARGING_CABLE_LOCK_FAILED = 43;

// The electric vehicle (EV) charging cable is invalid.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_CHARGING_CABLE_INVALID = 43;
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_CHARGING_CABLE_INVALID = 44;

// The incompatible electric vehicle (EV) charging plug is invalid.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_CONSUMER_INCOMPATIBLE = 44;
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_EV_CONSUMER_INCOMPATIBLE = 45;

// There is a battery system imbalance.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_BATTERY_IMBALANCE = 50;
Expand All @@ -329,6 +376,28 @@ enum ElectricalComponentDiagnosticCode {

// The battery's DC contactor or relays have reached end of life.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_RELAY_CYCLE_LIMIT_REACHED = 60;

// The PV panels have been connected with reversed polarity.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_PV_REVERSAL_POLARITY = 70;

// The PV panels are underperforming.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_PV_UNDERPERFORMANCE = 71;

// The PV panels have a fault.
// The component is not able to determine or specify the fault.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_PV_FAULT = 72;

// The PV panels are receiving a reverse current.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_PV_REVERSE_CURRENT = 73;

// The PV panels are not grounded properly.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_PV_GROUND_FAULT = 74;

// The inverter is inoperable due to the DC voltage being too low.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_INVERTER_DC_UNDERVOLTAGE = 80;

// The inverter is inoperable due to the DC voltage being too high.
ELECTRICAL_COMPONENT_DIAGNOSTIC_CODE_INVERTER_DC_OVERVOLTAGE = 81;
}