DontLetYourVegetablesDie!
For the deploy on the Raspberry device:
- The Rasberry device port 5000 will be visible online through a service called Ngrok
- There is a small server (
deploy/syncServer.py) that accepts requests onPOST /webhook :5000 - On valid requests the servers pulls the content of this repository on the branch
main(or otherwise the specified one in the args) and restart the systemd service related to this project - Github is configured to call the small server with WebHooks each time some code is pushed
- Setup your ngrok account and obtain an API token
- Clone repository on your device in
$HOME/verderamen - Fix your environment inside
verderamen/.env(add NGROK_STATIC_DOMAIN, NGROK_APP_TOKEN) - Run
pipenv run install
The syncServer should be running as systemd service verderamen-syncer, this service will sync automatically the just cloned repository and restart the systemd service verderamen that is the actual application.
This application checks weather forecast with Weather API and assigns a score (from 0 to 1) that will be decisive in determining whether to irrigate or not (0 no water, 1 max time possible). The score is calculated with a weighted mean with some scores derived from temperature, humidity and rain (when under 2mm/24hours). If in the next 24 hours it will rain above 2mm/24hours the weather water score (WWS) will be definitely 1.
The weather will be checked within WEATHER_CHECK_AT_TIME_RANGE_MINUTES minutes from WEATHER_CHECK_AT_TIME once a day and will keep the forecast data until the next day. In case of errors it will retry till success.
| Description | Data |
|---|---|
| API Example | weather-api.json |
| Class | /verderamen/services/weather.py |
The weather score system is based on this configuration keys:
WEATHER_ENABLED(optional, boolean, default: True): Enable weather moduleWEATHER_API_API_KEY(required, string): API Key for Weather API forecastWEATHER_COORDINATES(required, string/lat,lng): Coordinates to use for the weather forecastWEATHER_API_BASE_URL(optional, string/URL, default: https://api.weatherapi.com/): base URL for Weather APIWEATHER_API_FORECAST_PATH(optional, string/URL-path, default: /v1/forecast.json): path for Weather API forecastWEATHER_WATER_HIGH_TEMPERATURE(optional, integer/Celsius, default: 40): high weather that will determine max water scoreWEATHER_WATER_LOW_TEMPERATURE(optional, integer/Celsis, default: 0): low weather that will determine low water scoreWEATHER_WATER_TEMPERATURE_SCORE_WEIGHT(optional, float/[0, 1], default: 0.8): how much temperature will influence final weather score (0 nothing, 1 all)WEATHER_WATER_HUMIDITY_SCORE_WEIGHT(optional, float/[0, 1], default: 0.3): how much humidity will influence final weather score (0 nothing, 1 all)WEATHER_WATER_LOW_RAIN_SCORE_WEIGHT(optional, string/[0, 1], default: 1): how much low rain (under 2mm of rain in a dat) will influence final weather score (0 nothing, 1 all)WEATHER_CHECK_AT_TIME(optional, string/12:00 AM, default: 06:00 AM): At what time the weather will be checked (once a day)WEATHER_CHECK_AT_TIME_RANGE_MINUTES(optional, int/minutes, default: 5): Range before and afterWEATHER_CHECK_AT_TIMEin which the weather will be checked
| Description | Data |
|---|---|
| Sensor model | HC-SR04 |
| Specs | https://cdn.sparkfun.com/datasheets/Sensors/Proximity/HCSR04.pdf |
| Voltage | 5V |
| Current | 12mA |
| Class | /verderamen/io/tank_level.py |
The ECHO PIN is wired to the Rasberry with 1KOhm + 2KOhm resistors since the Raspberry GPIO works at 3.3V while HC-SR04 at 5V.
For the tank level a HC-SR04 ultrasonic sensor is used. For this component these environment variables should be set:
TANK_LEVEL_OUT_PIN(required, integer): out pin for sensorTANK_LEVEL_IN_PIN(required, integer): in (echo) pin for sensorTANK_LEVEL_MIN_DISTANCE_CM(required, number): specified minimum distance that will determine 0% levelTANK_LEVEL_MAX_DISTANCE_CM(required, number): specified maximum distance that will determine 100% level
| Description | Data |
|---|---|
| Sensor model | FPD-270A |
| Specs | https://www.mantech.co.za/datasheets/products/FPD-270A-102-XXX_SGT.pdf |
| Voltage | 12V DC |
| Power | 5W |
| Resistance | 12v^2 / 5W = 28.8 Ohm |
| Current | 417mA |
| Other | Normally closed |
| Class | /verderamen/io/tank_level.py |
The valve is wired to a 12V DC Power supply. The ground is wired to a NPN Transistor Collector (specific model: PN2222). The base of the transistor is wired to GPIO PIN set by VALVE_TRANSISTOR_BASE_OUT_PIN with a resistor of 220 Ohms (calculated here). The emitter of the transitor is wired to ground. When the VALVE_TRANSISTOR_BASE_OUT_PIN is HIGH the valve will open, when LOW will be (default) closed.
Configuration:
VALVE_TRANSISTOR_BASE_OUT_PIN(required, integer): out pin for transitor BASE