added zone 4 and 5, when having extra vr70 coupled to system#524
Open
garageboxnv wants to merge 7 commits intojohn30:masterfrom
Open
added zone 4 and 5, when having extra vr70 coupled to system#524garageboxnv wants to merge 7 commits intojohn30:masterfrom
garageboxnv wants to merge 7 commits intojohn30:masterfrom
Conversation
|
This is a great addition - at least for me. I actually have 2 VR70s and 1 VR71. As far as I know this is the max setup. Can you consider adding Hc6 and Hc7 as well? Local config works more or less, though the online config files have also a number of benefits for normal users - like me. |
Author
|
Added also humidity in the TSP files for VRC700 as in this pull request was made in csv #521 Was only able to add the VRC700, I still have 2 VR91's but do not have the humidity yet of those. |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
I have added 2 extra zone/heating circuit definitions to the vrc700 definition, as my system is extended with another vr70 adding 2 zones
A suggestion for improvement could be to have the zone values be defined once abstract (maybe a template) and refer to this with the last byte in how many zones are defined. (e.g. Z1=0x0, Z2=0x1, Z3=0x2, Z4=0x3,...)
Theoretically a system can be extended with more vr70's
P.S. I like the improvement of templates, it gave me the possibility to understand the messages better