Skip to content

lamw/vcf-5x-in-box

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

2 Commits
 
 
 
 
 
 
 
 

Repository files navigation

VMware Cloud Foundation (VCF) 5.x in a Box

Deploy a fully functional VMware Cloud Foundation (VCF) 5.x environment running on a single physical ESXi host for development and lab purposes, with the goal of being able to explore and learn about VCF using a minimal amount of compute and storage resources.

Note: This is not using Nested ESXi such as the VCF Holodeck Solution

Table of Contents

Changelog

  • 05/28/2025
    • Fix ESXi BOM version (U3b) + Added Build numbers
  • 05/15/2025
    • Initial Release

Build of Materials (BOM)

Prereq

  • Minimum 4 VLANs (e.g. 30, 40, 50, 60) for VCF Management Domain
    • VLAN30 - Management
    • VLAN40 - vMotion
    • VLAN50 - vSAN
    • VLAN60 - NSX Host TEP
  • (Optional) Additional 3 VLANs (e.g. 70, 80 & 90) for VCF Edge Cluster for Workload Domain
    • VLAN70 - NSX Edge TEP
    • VLAN80 - Tier 0
    • VLAN90 - Tier 1
  • At least 6 IP Addresses/DNS for VCF Management Domain. Additional IP Address/DNS will be required for VCF Workload Domain along with deploying full Aria Suite
Hostname FQDN IP Address Function
dns dns.vcf.lab 172.30.0.2 DNS Server
cb cb.vcf.lab 172.30.0.4 VCF Cloud Builder
mgmt-esx01 mgmt-esx01.vcf.lab 172.30.0.10 Physical ESXi Server
mgmt-vc01 mgmt-vc01.vcf.lab 172.30.0.11 vCenter Server for Management Domain
mgmt-sddcm01 mgmt-sddcm01.vcf.lab 172.30.0.12 SDDC Manager
mgmt-nsx01 mgmt-nsx01.vcf.lab 172.30.0.13 NSX Manager VIP for Management Domain
mgmt-nsx01a mgmt-nsx01a.vcf.lab 172.30.0.14 NSX Manager for Management Domain
mgmt-lcm01 mgmt-lcm01.vcf.lab 172.30.0.18 Aria Suite Lifecycle Manager
mgmt-idm01 mgmt-idm01.vcf.lab 172.30.0.19 Aria Identity Manager
mgmt-ops01 mgmt-ops01.vcf.lab 172.30.0.20 Aria Operations
mgmt-logs01 mgmt-logs01.vcf.lab 172.30.0.21 Aria Operations for Logs
mgmt-auto01 mgmt-auto01.vcf.lab 172.30.0.22 Aria Automation
wld-esx01 wld-esx01.vcf.lab 172.30.0.30 Nested ESXi for Workload Domain
wld-vc01 wld-vc01.vcf.lab 172.30.0.31 vCenter Server for Workload Domain
wld-nsx01 wld-nsx01.vcf.lab 172.30.0.32 NSX Manager VIP for Workload Domain
wld-nsx01a wld-nsx01a.vcf.lab 172.30.0.33 NSX Manager for Workload Domain

Installation

  1. Download both the ESXi ISO (VMware-VMvisor-Installer-8.0U3-24022510.x86_64.iso) and VCF Cloud Builder OVA (**VMware-Cloud-Builder-5.2.1.0-24307856_OVF10.ova) to your local desktop.

  2. Create a bootable ESXi installer using the ESXi ISO using UNetbootin

  3. We will be performing a scripted installation of ESXi (aka ESXi Kickstart) to remove the number of manual steps that would be needed during the post-installation of ESXi.

  4. Edit the KS.CFG and replace the following values with your own desired configurations:

network --bootproto=static --ip=172.30.0.10 --netmask=255.255.255.0 --gateway=172.30.0.1 --hostname=mgmt-esx01.vcf.lab --nameserver=172.30.0.2 --addvmportgroup=1
rootpw VMware1!

...

ESXI_NVME_TIERING_AND_OSDATA_AND_VMFS="t10.NVMe____Samsung_SSD_990_EVO_2TB_________________C604A0412C382500"
NVME_TIERING_SIZE_IN_GB=320
OSDATA_SIZE_IN_GB=64
VMFS_DATASTORE_NAME="local-vmfs-datastore"
NTP_SERVER=104.167.215.195

Note: In order to identify the NVMe device label for tje ESXI_NVME_TIERING_AND_OSDATA_AND_VMFS variable, you will need to boot the ESXi installer intially and switch to console (ALT+F1) and login with root and blank for the password (just hit enter). Enable SSH /etc/init.d/SSH start and then identify the IP Address which will allow you to SSH to ESXi host, which is running in memory and run the vdq -q command and list all storage devices. Identify the device you wish to use for ESX OS-Data, NVMe Tiering & local VMFS and make a note of the label as shown in the screenshot below.

After creating the bootable ESXi installer on your USB device, copy your modified KS.CFG into the root directory of the USB device.

Now, navigate into the USB device under EFI/BOOT and edit BOOT.CFG and update the kernelopt so it matches the followingn which will run our KS.CFG instead of the interactive installation:

bootstate=0
title=Loading ESXi installer
timeout=5
prefix=
kernel=/b.b00
kernelopt=ks=usb:/KS.CFG
modules=/jumpstrt.gz --- /useropts.gz --- /features.gz --- /k.b00 --- /uc_intel.b00 --- /uc_amd.b00 --- /uc_hygon.b00 --- /procfs.b00 --- /vmx.v00 --- /vim.v00 --- /tpm.v00 --- /sb.v00 --- /s.v00 --- /atlantic.v00 --- /bcm_mpi3.v00 --- /bnxtnet.v00 --- /bnxtroce.v00 --- /brcmfcoe.v00 --- /cndi_igc.v00 --- /dwi2c.v00 --- /elxiscsi.v00 --- /elxnet.v00 --- /i40en.v00 --- /iavmd.v00 --- /icen.v00 --- /igbn.v00 --- /intelgpi.v00 --- /ionic_cl.v00 --- /ionic_en.v00 --- /irdman.v00 --- /iser.v00 --- /ixgben.v00 --- /lpfc.v00 --- /lpnic.v00 --- /lsi_mr3.v00 --- /lsi_msgp.v00 --- /lsi_msgp.v01 --- /lsi_msgp.v02 --- /mtip32xx.v00 --- /ne1000.v00 --- /nenic.v00 --- /nfnic.v00 --- /nhpsa.v00 --- /nipmi.v00 --- /nmlx5_cc.v00 --- /nmlx5_co.v00 --- /nmlx5_rd.v00 --- /ntg3.v00 --- /nvme_pci.v00 --- /nvmerdma.v00 --- /nvmetcp.v00 --- /nvmxnet3.v00 --- /nvmxnet3.v01 --- /pvscsi.v00 --- /qcnic.v00 --- /qedentv.v00 --- /qedrntv.v00 --- /qfle3.v00 --- /qfle3f.v00 --- /qfle3i.v00 --- /qflge.v00 --- /rdmahl.v00 --- /rshim_ne.v00 --- /rshim.v00 --- /rste.v00 --- /sfvmk.v00 --- /smartpqi.v00 --- /vmkata.v00 --- /vmksdhci.v00 --- /vmkusb.v00 --- /vmw_ahci.v00 --- /bmcal.v00 --- /clusters.v00 --- /crx.v00 --- /drivervm.v00 --- /elx_esx_.v00 --- /btldr.v00 --- /dvfilter.v00 --- /esx_ui.v00 --- /esxupdt.v00 --- /tpmesxup.v00 --- /weaselin.v00 --- /esxio_co.v00 --- /infravis.v00 --- /loadesx.v00 --- /lsuv2_hp.v00 --- /lsuv2_in.v00 --- /lsuv2_ls.v00 --- /lsuv2_nv.v00 --- /lsuv2_oe.v00 --- /lsuv2_oe.v01 --- /lsuv2_sm.v00 --- /native_m.v00 --- /qlnative.v00 --- /trx.v00 --- /vcls_pod.v00 --- /vdfs.v00 --- /vds_vsip.v00 --- /vmware_e.v00 --- /hbrsrv.v00 --- /vsan.v00 --- /vsanheal.v00 --- /vsanmgmt.v00 --- /tools.t00 --- /xorg.v00 --- /gc.v00 --- /imgdb.tgz --- /basemisc.tgz --- /resvibs.tgz --- /esxiodpt.tgz --- /imgpayld.tgz
build=8.0.3-0.35.24280767
updated=0
  1. Plug the USB device into your system and power on to begin the ESXi installation. If you are performing a scripted installation, you may come across this warning, you can ignore and either wait or press enter to continue with the installation

  1. Once the ESXi reboot (there is a secondary reboot as part of the ESXi scripted installation), you should be able to login to your ESXi host using the FQDN and see something like the following:

  1. Install the vSAN ESA Mock VIB which will allow us to use non-HCL NVMe devices for configuring vSAN ESA
esxcli network firewall ruleset set -e true -r httpClient
esxcli software acceptance set --level CommunitySupported
esxcli software vib install -v https://github.com/lamw/nested-vsan-esa-mock-hw-vib/releases/download/1.0/nested-vsan-esa-mock-hw.vib --no-sig-check
/etc/init.d/vsanmgmtd restart
  1. (Optional) If you do not already have a DNS server running within your enviornment or would like to localized this setup, you can deploy a VMware PhotonOS VM and use that as your DNS server. You can use my unbound.conf as an exmaple setup.
tdnf update -y
tdnf install unbound -y
systemctl stop iptables
systemctl disable iptables
systemctl enable unbound
systemctl restart unbound

rm -f /etc/resolv.conf
cat > /etc/resolv.conf <<EOF
nameserver 172.30.0.2
search vcf.lab
EOF
  1. Deploy the Cloud Builder Appliance by using the ESXi Embedded Host Client or you can automate (recommend) it by using following script deploy_vcf_cloudbuilder.sh.

  1. After Cloud Builder is up and running, we will need to make a few configuration changes. SCP the setup_vmware_cloud_builder_for_one_node_management_domain.sh to the Cloud Builder appliance using the admin username and the credentials configured from the previous step.

You will need to run the script as the root user by switching to that user and provide the root credentials when prompted after running the following command:

su -

  1. We are now ready to deploy the VCF Management Domain using Cloud Builder. Edit the vcf52-management-domain-example.json and replace the values with your desired configuration.

We will use the Cloud Builder UI interface (open a browser to the FQDN of Cloud Builder) to validate vcf52-management-domain-example.json configuration. The only error that you should see is 10GbE NIC pre-check which will fail and this is to be expected. If you have any other errors, please resolve those and re-submit your JSON for validation.

To bypass the 10GbE NIC pre-check, we will need to deploy the VCF Management Domain using the Cloud Builder REST API instead of the UI. Update the deploy-vcf-mgmt-domain.ps1 PowerShell script with your desired values.

Run the PowerShell as shown below and if the operation was successfull, you can now use the Cloud Builder UI to monitor the progress of your deployment.

./deploy-vcf-mgmt-domain.ps1

  1. The Cloud Builder will encounter an expected failure when it attempts to deploy NSX Manager due to default VM Storage Policy set for vSAN ESA.

Open a new browser window to the FQDN of the deployed vCenter Server and navigate to the VM Storage Policies and locate vcf-m01-cl01 - Optimal Datastore Default Policy - RAID1 and set the value for "Failures to tolerate" to No data redundancy and apply the change.

Navigate back to the Cloud Builder UI and then retry the deployment which will resume and now continue the deployment.

Here is what the Cloud Builder UI should look like upon completing the VCF Management Domain bring-up.

Once you click finished, you will have option to login to SDDC Manager

Here is a screenshot of the ESXi host and expected inventory once the VCF Management Domain has been deployed. At this point, you can shutdown the Cloud Builder VM as it is no longer required.

To get rid of the the Insufificent vSphere HA warning in vSphere UI, you can edit the vSphere HA setings and disable Admission Control.

Additional Deployments

Workload Domain

If you wish to deploy a Workload Domain, you will need to deploy Nested ESXi VM(s) due to the 10GbE pre-check requirement. After comissioning additional ESXi hosts, you can deploy Worklaod Domain using the SDDC Manager UI or SDDC Manager API which you can refer to vcf52-workload-domain-example.json as a working example.

Edge Cluster for Workload Domain

For additional networking capablitites, you can deploy an [NSX Edge Cluster for your Workload Domain](https://techdocs.broadcom.com/us/en/vmware-cis/vcf/vcf-5-2-and-earlier/4-5/administering/deploying-nsx-edge-clusters-admin.html which will require at least two ESXi hosts within the Workload Domain. You can deploy using the SDDC Manager UI or API, you can refer to wld-edge-cluster.json as a working example when using the API.

Aria Suite

If you wish to deploy Aria Suite (Aria Identity, Aria Operations, Aria Operations for Logs and Aria Operations for Network) using Aria Lifecycle Manager, you can download it from HERE

Blog References

About

Minimal VMware Cloud Foundation (VCF) 5.x in a box

Resources