Skip to content

Conversation

@SpacePlushy
Copy link

Summary

Fixes #5237

When using -U MACRO (with space) in build_flags, SCons' ParseFlags() splits it into two separate items in CCFLAGS: ['-U', 'MACRO']. The previous code only captured '-U' and attempted undef[2:] which resulted in an empty string.

Changes

This PR modifies the ProcessFlags function in platformio/builder/tools/piobuild.py to:

  1. Iterate through CCFLAGS with an index to detect standalone -U flags
  2. Pair -U with the following macro name when they're separate items
  3. Handle both formats:
    • -UMACRO (no space) - already working ✓
    • -U MACRO (with space) - now fixed ✓

The solution follows a similar pattern to how SCons handles -D flags with spaces.

Testing

Verified the fix handles:

  • Single -U MACRO format with space
  • Single -UMACRO format without space
  • Mixed formats in the same build_flags
  • Multiple undefines

Example

Before (broken):

build_flags = -U LORA_TX_POWER

Result: Only -U captured, macro name lost

After (fixed):

build_flags = -U LORA_TX_POWER

Result: Correctly passes -U LORA_TX_POWER to gcc

Fixes platformio#5237

When using '-U MACRO' (with space) in build_flags, SCons' ParseFlags()
splits it into two separate items in CCFLAGS: ['-U', 'MACRO']. The
previous code only captured '-U' and attempted undef[2:] which resulted
in an empty string.

This fix iterates through CCFLAGS with an index to detect standalone
'-U' flags and pairs them with the following macro name. Both formats
are now supported:
- '-UMACRO' (no space) - already working
- '-U MACRO' (with space) - now fixed

The solution is similar to how SCons handles '-D' flags with spaces.
@CLAassistant
Copy link

CLAassistant commented Oct 29, 2025

CLA assistant check
All committers have signed the CLA.

@SpacePlushy
Copy link
Author

Note on testing:

In my initial comment on #5237, I mentioned including tests with this PR. After exploring the codebase, I noticed there aren't existing unit tests for the builder tools (specifically for ProcessFlags and related functions in piobuild.py).

I didn't want to add a new test structure without understanding your preferred testing approach for the builder module. I'm happy to add tests if you'd like - just let me know:

  1. Should I create a new test file for builder tools?
  2. Is there a preferred testing pattern you'd like me to follow?
  3. Or would you prefer to handle testing separately?

I manually verified the fix handles all edge cases (both -U MACRO and -UMACRO formats, mixed usage, etc.), but I'm ready to formalize that into proper tests if needed.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

Undefines in build_flags don't work if there's a space after -U