3 changes: 3 additions & 0 deletions docs/sphinx/source/whatsnew/v0.11.2.rst
Original file line number Diff line number Diff line change
Expand Up @@ -47,6 +47,9 @@ Documentation
page, using the sphinx glossary directive. (:issue:`1421`, :pull:`2234`)
* Explained how to write docstrings for new functions in :ref:`example-docstring`
(:discussion:`2081`, :pull:`2254`)
* Clarify mounting cases for parameters for :py:func:`~pvlib.temperature.sapm_module`
:py:func:`~pvlib.temperature.sapm_cell` and :py:func:`~pvlib.temperature.pvsyst_cell`.
(:issue:`1323`, :pull:`2293`)
* Added the following variables to the :ref:`nomenclature` page:

- `spectra` and `spectra_components` (:issue:`2150`, :pull:`2264`)
Expand Down
25 changes: 16 additions & 9 deletions pvlib/pvsystem.py
Original file line number Diff line number Diff line change
Expand Up @@ -168,9 +168,11 @@ class PVSystem:
Inverter parameters as defined by the SAPM, CEC, or other.

racking_model : string, optional
Valid strings are 'open_rack', 'close_mount', 'freestanding',
'insulated', or 'insulated_back'.
Used to identify a parameter set for the cell temperature model.
Valid strings are ``'open_rack'``, ``'close_mount'``,
``'freestanding'``, and ``'insulated_back'`. Used to identify a
parameter set for the SAPM cell temperature model.
See :py:func:`~pvlib.temperature.sapm_module` and
:py:func:`~pvlib.temperature.pvsyst_cell` for definitions.

losses_parameters : dict or Series, optional
Losses parameters as defined by PVWatts or other.
Expand Down Expand Up @@ -1393,9 +1395,11 @@ class FixedMount(AbstractMount):
West=270. [degrees]

racking_model : str, optional
Valid strings are 'open_rack', 'close_mount', 'freestanding',
'insulated', or 'insulated_back'.
Used to identify a parameter set for the cell temperature model.
Valid strings are ``'open_rack'``, ``'close_mount'``,
``'freestanding'``, and ``'insulated_back'`. Used to identify a
parameter set for the SAPM cell temperature model.
See :py:func:`~pvlib.temperature.sapm_module` and
:py:func:`~pvlib.temperature.pvsyst_cell` for definitions.

module_height : float, optional
The height above ground of the center of the module [m]. Used for
Expand Down Expand Up @@ -1471,9 +1475,12 @@ class SingleAxisTrackerMount(AbstractMount):
`cross_axis_tilt`. [degrees]

racking_model : str, optional
Valid strings are 'open_rack', 'close_mount', 'freestanding',
'insulated', or 'insulated_back'.
Used to identify a parameter set for the cell temperature model.
Valid strings are ``'open_rack'``, ``'close_mount'``,
``'freestanding'``, and ``'insulated_back'`. Used to identify a
parameter set for the SAPM cell temperature model.
``'open_rack'`` should be used for systems with single-axis trackers.
See :py:func:`~pvlib.temperature.sapm_module` and
:py:func:`~pvlib.temperature.pvsyst_cell` for definitions.

module_height : float, optional
The height above ground of the center of the module [m]. Used for
Expand Down
46 changes: 46 additions & 0 deletions pvlib/temperature.py
Original file line number Diff line number Diff line change
Expand Up @@ -125,6 +125,18 @@ def sapm_cell(poa_global, temp_air, wind_speed, a, b, deltaT,
| glass/polymer | insulated back | -2.81 | -0.0455 | 0 |
+---------------+----------------+-------+---------+---------------------+

Mounting cases can be described in terms of air flow across and around the
rear-facing surface of the module:

* "open rack" refers to mounting that allows relatively free air flow.
This case is typical of ground-mounted systems on fixed racking or
single axis trackers.
* "close roof" refers to limited or restricted air flow. This case is
typical of roof-mounted systems with some gap behind the module.
* "insulated back" refers to systems with no air flow contacting the rear
surface of the module. This case is typical of building-integrated PV
systems, or systems laid flat on a ground surface.

References
----------
.. [1] King, D. et al, 2004, "Sandia Photovoltaic Array Performance
Expand Down Expand Up @@ -206,6 +218,18 @@ def sapm_module(poa_global, temp_air, wind_speed, a, b):
| glass/polymer | insulated back | -2.81 | -0.0455 | 0 |
+---------------+----------------+-------+---------+---------------------+

Mounting cases can be described in terms of air flow across and around the
rear-facing surface of the module:

* "open rack" refers to mounting that allows relatively free air flow.
This case is typical of ground-mounted systems on fixed racking or
single axis trackers.
* "close roof" refers to limited or restricted air flow. This case is
typical of roof-mounted systems with some gap behind the module.
* "insulated back" refers to systems with no air flow contacting the rear
surface of the module. This case is typical of building-integrated PV
systems, or systems laid flat on a ground surface.

References
----------
.. [1] King, D. et al, 2004, "Sandia Photovoltaic Array Performance
Expand Down Expand Up @@ -276,6 +300,18 @@ def sapm_cell_from_module(module_temperature, poa_global, deltaT,
| glass/polymer | insulated back | -2.81 | -0.0455 | 0 |
+---------------+----------------+-------+---------+---------------------+

Mounting cases can be described in terms of air flow across and around the
rear-facing surface of the module:

* "open rack" refers to mounting that allows relatively free air flow.
This case is typical of ground-mounted systems on fixed racking or
single axis trackers.
* "close roof" refers to limited or restricted air flow. This case is
typical of roof-mounted systems with some gap behind the module.
* "insulated back" refers to systems with no air flow contacting the rear
surface of the module. This case is typical of building-integrated PV
systems, or systems laid flat on a ground surface.

References
----------
.. [1] King, D. et al, 2004, "Sandia Photovoltaic Array Performance
Expand Down Expand Up @@ -360,6 +396,16 @@ def pvsyst_cell(poa_global, temp_air, wind_speed=1.0, u_c=29.0, u_v=0.0,
| insulated | 15.0 | 0.0 |
+--------------+---------------+---------------+

Mounting cases can be described in terms of air flow across and around the
rear-facing surface of the module:

* "freestanding" refers to mounting that allows relatively free air
circulation around the modules. This case is typical of ground-mounted
systems on tilted, fixed racking or single axis trackers.
* "insluated" refers to mounting with air flow across only the front
surface. This case is typical of roof-mounted systems with no gap
behind the module.

References
----------