Notifications
You must be signed in to change notification settings - Fork 1.1k
add marion's adjustment to pvwatts_dc #2569
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
base: main
Are you sure you want to change the base?
Changes from all commits
05f5408
6d7ae12
40328c8
a9dfb28
551e722
73e80d3
f25b426
380bb58
5d31dfd
ad146b5
69ce5e7
dc58507
0d8b0b5
90b7c54
1297448
4488e3c
250af5a
bd16ac2
f3041c2
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -2878,19 +2878,10 @@ | |
|
||
@renamed_kwarg_warning( | ||
"0.13.0", "g_poa_effective", "effective_irradiance") | ||
def pvwatts_dc(effective_irradiance, temp_cell, pdc0, gamma_pdc, temp_ref=25.): | ||
def pvwatts_dc(effective_irradiance, temp_cell, pdc0, gamma_pdc, temp_ref=25., | ||
k=None, cap_adjustment=False): | ||
r""" | ||
Implements NREL's PVWatts DC power model. The PVWatts DC model [1]_ is: | ||
|
||
.. math:: | ||
|
||
P_{dc} = \frac{G_{poa eff}}{1000} P_{dc0} ( 1 + \gamma_{pdc} (T_{cell} - T_{ref})) | ||
|
||
Note that ``pdc0`` is also used as a symbol in | ||
:py:func:`pvlib.inverter.pvwatts`. ``pdc0`` in this function refers to the DC | ||
power of the modules at reference conditions. ``pdc0`` in | ||
:py:func:`pvlib.inverter.pvwatts` refers to the DC power input limit of | ||
the inverter. | ||
Implement NREL's PVWatts (Version 5) DC power model. | ||
|
||
Parameters | ||
---------- | ||
|
@@ -2909,22 +2900,88 @@ | |
temp_ref: numeric, default 25.0 | ||
Cell reference temperature. PVWatts defines it to be 25 C and | ||
is included here for flexibility. [C] | ||
k: numeric, optional | ||
Irradiance correction factor, defined in [2]_. Typically positive. | ||
[unitless] | ||
cap_adjustment: Boolean, default False | ||
If True, apply the optional adjustment at and below 1000 W/m^2. | ||
|
||
Returns | ||
------- | ||
pdc: numeric | ||
DC power. [W] | ||
|
||
Notes | ||
----- | ||
The PVWatts Version 5 DC model [1]_ is: | ||
|
||
.. math:: | ||
|
||
P_{dc} = \frac{G_{poa eff}}{1000} P_{dc0} ( 1 + \gamma_{pdc} (T_{cell} - T_{ref})) | ||
|
||
This model has also been referred to as the power temperature coefficient | ||
model. | ||
|
||
This function accepts an optional irradiance adjustment factor, `k`, based | ||
on [2]_. This applies a piece-wise adjustment to power based on irradiance, | ||
where `k` is the reduction in actual power at 200 Wm⁻² relative to power | ||
calculated at 200 Wm-2 as 0.2*`pdc0`. For example, a 500 W module that | ||
produces 95 W at 200 Wm-2 (a 5% relative reduction in efficiency) would | ||
have a value of `k` = 0.01. | ||
|
||
.. math:: | ||
|
||
k=\frac{0.2P_{dc0}-P_{200}}{P_{dc0}} | ||
|
||
For positive `k` values, and `k` is typically positive, this adjustment | ||
increases relative efficiency when irradiance is above 1000 Wm⁻². This may | ||
not be desired, as modules with nonlinear irradiance response often have | ||
peak efficiency near 1000 Wm⁻², and it is either flat or declining at | ||
higher irradiance. An optional parameter, `cap_adjustment`, can address | ||
this by modifying the adjustment from [2]_ to only apply below 1000 Wm⁻². | ||
|
||
Note that ``pdc0`` is also used as a symbol in | ||
:py:func:`pvlib.inverter.pvwatts`. ``pdc0`` in this function refers to the DC | ||
power of the modules at reference conditions. ``pdc0`` in | ||
:py:func:`pvlib.inverter.pvwatts` refers to the DC power input limit of | ||
the inverter. | ||
|
||
References | ||
---------- | ||
.. [1] A. P. Dobos, "PVWatts Version 5 Manual" | ||
http://pvwatts.nrel.gov/downloads/pvwattsv5.pdf | ||
(2014). | ||
.. [2] B. Marion, "Comparison of Predictive Models for | ||
Photovoltaic Module Performance," | ||
:doi:`10.1109/PVSC.2008.4922586`, | ||
https://docs.nrel.gov/docs/fy08osti/42511.pdf | ||
(2008). | ||
""" # noqa: E501 | ||
|
||
pdc = (effective_irradiance * 0.001 * pdc0 * | ||
(1 + gamma_pdc * (temp_cell - temp_ref))) | ||
|
||
# apply Marion's correction if k is anything but zero | ||
if k is not None: | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. needing to use the |
||
err_1 = k * (1 - (1 - effective_irradiance / 200)**4) | ||
err_2 = k * (1000 - effective_irradiance) / (1000 - 200) | ||
|
||
pdc_marion = np.where(effective_irradiance <= 200, | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. np.where will break the paradigm of "return the same object type that was input" since it always returns an array. Options:
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I see what you mean. I tried a few things, but can’t seem to figure out how to get your proposed solutions to work. Any pointers or examples? |
||
pdc - (pdc0 * err_1), | ||
pdc - (pdc0 * err_2)) | ||
|
||
# "cap" Marion's correction at 1000 W/m^2 | ||
if cap_adjustment: | ||
pdc_marion = np.where(effective_irradiance >= 1000, | ||
pdc, | ||
pdc_marion) | ||
|
||
# large k values can result in negative power at low irradiance, so | ||
# set negative power to zero | ||
pdc_marion[pdc_marion < 0] = 0 | ||
|
||
pdc = pdc_marion | ||
|
||
return pdc | ||
|
||
|
||
|
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@wholmgren, does this help with clarifying the deviation?