Why I did it

BCM fixed the KNET packet issue reported in CS00012426701 by using the PTCH with system port instead of PTCH2 with PP_PORT. This change was done to support the dynamic port speed change by removing the port and creating a port in SAI.

Work item tracking
  • Microsoft ADO (number only):

How I did it

Updated the BCM config files to use PTCH header instead of PTCH2 for Nokia DNX platforms.

How to verify it

Verified all the control protocols are up with BCM config change and the BCM SAI fix provided for CS00012426701.

Which release branch to backport (provide reason below if selected)

  • 202205
  • 202211
  • 202305
  • 202311
  • 202405
  • 202411
  • 202505

Tested branch (Please provide the tested image version)

Description for the changelog

Link to config_db schema for YANG module changes

A picture of a cute animal (not mandatory but encouraged)

…instead of PTCH2 for the CPU/KNET originated packets

Signed-off-by: saksarav <[email protected]>
@mssonicbld
Copy link
Collaborator

/azp run Azure.sonic-buildimage

@azure-pipelines
Copy link

Azure Pipelines successfully started running 1 pipeline(s).