…changes Updated recommendations for battery leads and wire materials, including notes on wire length and CCA usage.
sciencewhiz
reviewed
Mar 24, 2026
| #### Lead Cables | ||
|
|
||
| Tinned, annealed, or coated copper is allowed. Do not use CCA (copper clad aluminum), aluminum, or other non-copper base metal. The conductor metal is normally printed on the outside of the insulation with the other cable ratings. | ||
| Tinned, annealed, coated copper, or CCA (copper clad aluminum) is allowed. Do not use regular aluminum wire, or other non-copper base metal. The conductor metal is normally printed on the outside of the insulation with the other cable ratings. |
Collaborator
There was a problem hiding this comment.
It's my understanding that FIRST only made CCA legal to avoid teams having to rewire at inspection if they used the wrong wire. Thus I think I'd prefer to keep CCA in the do not use to absolutely minimize the number of teams that end up using it
Author
|
I would also prefer to keep it in the do not use category and certainly do not want to encourage using it. There was a lot of back and forth on the LRI slack about it and it is considered fully legal now though. I could rewrite to leave most of the original text and just add a note or warning section that says it is allowed but shouldn't be used? I don't want people to see it is allowed in the manual and buy it because it's cheaper. Thoughts?ThanksOn Mar 23, 2026 11:43 PM, sciencewhiz ***@***.***> wrote:
@sciencewhiz commented on this pull request.
In source/docs/hardware/hardware-basics/robot-battery.rst:
#### Lead Cables
…-Tinned, annealed, or coated copper is allowed. Do not use CCA (copper clad aluminum), aluminum, or other non-copper base metal. The conductor metal is normally printed on the outside of the insulation with the other cable ratings.
+Tinned, annealed, coated copper, or CCA (copper clad aluminum) is allowed. Do not use regular aluminum wire, or other non-copper base metal. The conductor metal is normally printed on the outside of the insulation with the other cable ratings.
It's my understanding that FIRST only made CCA legal to avoid teams having to rewire at inspection if they used the wrong wire. Thus I think I'd prefer to keep CCA in the do not use to absolutely minimize the number of teams that end up using it
—Reply to this email directly, view it on GitHub, or unsubscribe.You are receiving this because you authored the thread.Message ID: ***@***.***>
|
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Updated recommendations for battery leads and wire materials, including notes on wire length and CCA usage from 2025/2026 rule changes