19 changes: 14 additions & 5 deletions doc/AC.md
Original file line number Diff line number Diff line change
Expand Up @@ -17,22 +17,31 @@

## Customize

- Set the temperature step of AC (0.5 by default).
### Temperature setting step of AC

Default step: 0.5

```json
{ "temperature_step": 1 }
```

- Power consumption analysis method (1 by default)
### Power consumption analysis method

There are 4 different methods to decode the consumption of an AC, but we don’t know which is right for your device.
If the power and/or energy consumption data looks incorrect, try another method and see if they are correct.
The options are 1 (binary), 2 (BCD), 3 (base/radix 100) and 12 (BCD like #2, but with an additional /10 divider for the energy values).

There are 3 different methods to analyze the power consumption of an AC, but I don’t know which is right for your device.
If the power consumption data looks incorrect, try another method and see if they are correct.
The options include 1, 2, and 3.
Default mode: 1

```json
{ "power_analysis_method": 2 }
```

Known settings:
| Device | Mode |
| :------------------------------- | ---: |
| Midea PortaSplit | 12 |

## Entities

### Default entity
Expand Down
Loading