ADS1100 is a 16-Bit, 128SPS, 1-Ch Delta-Sigma Analogue to Digital converted made by Texas Instruments. The unit uses only external reference - the same as VDD. It is convenient to measure resistance rather than absolute voltages.
It is a minimalistic library that supports basic operations and continuous as well as single conversion modes.
See more details at [Texas Instruments](http://www.ti.com/product/ADS1100).begin()
Parameters: None
Description: Starts the I2C communication (Wire.begin) with the ADS1100 unit
Returns: None
getvalue()
Parameters: None
Description: Reads the ADC value data regardless of the fact it is recent or not. Works (obligatory) in continuous reading mode, optional in the single mode. Read the value int16_t instead.
Returns: int16_t (can be negative if Vin- is not wired to GND. If wired to GND, a slight negative value is still possible
configure(uint8_t singleMode, uint8_t dataRate, uint8_t gain)
Parameters: None
Description: Configures the operation mode of the ADS1100 unit
Details: (ADS1100_CONVERSION_SINGLE or ADS1100_CONVERSION_CONTINOUS, ADS1100_DATA_RATE_128SPS or ADS1100_DATA_RATE_32SPS or ADS1100_DATA_RATE_16SPS or ADS1100_DATA_RATE_8SPS, ADS1100_GAIN_1X or ADS1100_GAIN_2X or ADS1100_GAIN_4X or ADS1100_GAIN_8X)
Returns: None
conversionDone()
Parameters: None
Description: Checks (i) if the conversion is completed and ii) reads the ADC value. If the conversion is not completed yet, the ADC value is the old one
Returns: 1 if the conversion is completed, 0 otherwise
startSingleConversion()
Parameters: None
Description: Requests the unit to start the reading the ADC value. The reading actually takes the whole reading time
Returns: None
Continuous_read
The example shows continuous reading from the unit. The user is responsible for ensuring that the reading is properly updated. Reading the value before it is acquired will result in receiving old values.
Single_read
The example reads ADC data from the unit and performs conversion only when requested. The user is responsible for ensuring that the reading is properly updated. Reading the value before it is acquired will result in receiving old values.
Single_read_if_ready
The example reads ADC data from the unit and performs conversion only when requested.continuous reading from the unit. The output is performed only when conversion is performed actively checking for this condition.