Skip to content
Open
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
134 changes: 121 additions & 13 deletions zhaquirks/schneiderelectric/dimmers.py
Original file line number Diff line number Diff line change
@@ -1,35 +1,143 @@
"""Schneider Electric dimmers and switches quirks."""

from zigpy.quirks.v2 import QuirkBuilder
from zigpy.quirks.v2 import EntityPlatform, EntityType, QuirkBuilder
from zigpy.quirks.v2.homeassistant import UnitOfTime
from zigpy.quirks.v2.homeassistant.number import NumberDeviceClass

from zhaquirks.schneiderelectric import (
SE_MANUF_NAME,
SEBallast,
SEBasic,
SEControlMode,
SEDimmingCurve,
SEOnOff,
SEOnTimeReloadOptions,
SESwitchAction,
SESwitchConfiguration,
SESwitchIndication,
SEWiringMode,
)

(
QuirkBuilder(SE_MANUF_NAME, "NHROTARY/DIMMER/1")
.applies_to(SE_MANUF_NAME, "NHROTARY/UNIDIM/1")
.applies_to(SE_MANUF_NAME, "NHPB/DIMMER/1")
.applies_to(SE_MANUF_NAME, "NHPB/UNIDIM/1")
BASE_DIMMER = (
QuirkBuilder()
.replaces(SEBasic, endpoint_id=3)
.replaces(SEBallast, endpoint_id=3)
.replaces(SEOnOff, endpoint_id=3)
.number(
attribute_name=SEBallast.AttributeDefs.min_level.name,
cluster_id=SEBallast.cluster_id,
endpoint_id=3,
min_value=1,
max_value=254,
step=1,
fallback_name="Min light level",
translation_key="min_level",
)
.number(
attribute_name=SEBallast.AttributeDefs.max_level.name,
cluster_id=SEBallast.cluster_id,
endpoint_id=3,
min_value=1,
max_value=254,
step=1,
fallback_name="Max light level",
translation_key="max_level",
)
.number(
attribute_name=SEOnOff.AttributeDefs.se_on_time_reload.name,
cluster_id=SEOnOff.cluster_id,
endpoint_id=3,
min_value=0x0,
max_value=0xFFFFFFFF,
step=1,
unit=UnitOfTime.SECONDS,
device_class=NumberDeviceClass.DURATION,
translation_key="on_time_reload",
fallback_name="On time reload",
)
.number(
attribute_name=SEOnOff.AttributeDefs.se_pre_warning_time.name,
cluster_id=SEOnOff.cluster_id,
endpoint_id=3,
min_value=0x0,
max_value=0xFFFF,
step=1,
unit=UnitOfTime.SECONDS,
device_class=NumberDeviceClass.DURATION,
translation_key="pre_warning_time",
fallback_name="Pre warning time",
)
.enum(
endpoint_id=3,
cluster_id=SEOnOff.cluster_id,
attribute_name=SEOnOff.AttributeDefs.se_on_time_reload_options.name,
enum_class=SEOnTimeReloadOptions,
translation_key="on_time_reload_options",
fallback_name="On time reload options",
)
.enum(
endpoint_id=3,
cluster_id=SEBallast.cluster_id,
attribute_name=SEBallast.AttributeDefs.se_control_mode.name,
enum_class=SEControlMode,
translation_key="control_mode",
fallback_name="Control mode",
)
)

BASE_ROTARY_DIMMER = (
BASE_DIMMER.clone()
.replaces(SEBasic, endpoint_id=21)
.replaces(SESwitchConfiguration, endpoint_id=21)
.add_to_registry()
.enum(
endpoint_id=21,
cluster_id=SESwitchConfiguration.cluster_id,
attribute_name=SESwitchConfiguration.AttributeDefs.se_switch_indication.name,
enum_class=SESwitchIndication,
translation_key="switch_indication",
fallback_name="Switch indication",
)
.enum(
endpoint_id=21,
cluster_id=SESwitchConfiguration.cluster_id,
attribute_name=SESwitchConfiguration.AttributeDefs.se_switch_actions.name,
enum_class=SESwitchAction,
translation_key="switch_actions",
fallback_name="Switch actions",
)
)

(BASE_DIMMER.clone().applies_to(SE_MANUF_NAME, "PUCK/DIMMER/1").add_to_registry())

(
QuirkBuilder(SE_MANUF_NAME, "NHPB/SWITCH/1")
.applies_to(SE_MANUF_NAME, "CH2AX/SWITCH/1")
.replaces(SEBasic)
.replaces(SEOnOff)
.replaces(SEBasic, endpoint_id=21)
.replaces(SESwitchConfiguration, endpoint_id=21)
BASE_ROTARY_DIMMER.clone()
.applies_to(SE_MANUF_NAME, "NHROTARY/DIMMER/1")
.applies_to(SE_MANUF_NAME, "NHPB/DIMMER/1")
.applies_to(SE_MANUF_NAME, "CH/DIMMER/1")
.add_to_registry()
)

(
BASE_ROTARY_DIMMER.clone()
.applies_to(SE_MANUF_NAME, "NHROTARY/UNIDIM/1")
.applies_to(SE_MANUF_NAME, "NHPB/UNIDIM/1")
.enum(
endpoint_id=3,
cluster_id=SEBallast.cluster_id,
attribute_name=SEBallast.AttributeDefs.se_wiring_mode.name,
enum_class=SEWiringMode,
entity_platform=EntityPlatform.SENSOR,
entity_type=EntityType.DIAGNOSTIC,
translation_key="wiring_mode",
fallback_name="Wiring mode",
)
.enum(
endpoint_id=3,
cluster_id=SEBallast.cluster_id,
attribute_name=SEBallast.AttributeDefs.se_dimming_curve.name,
enum_class=SEDimmingCurve,
translation_key="dimming_curve",
fallback_name="Dimming curve",
)
.add_to_registry()
)
81 changes: 81 additions & 0 deletions zhaquirks/schneiderelectric/switches.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,81 @@
"""Schneider Electric switches quirks."""

from zigpy.quirks.v2 import QuirkBuilder
from zigpy.quirks.v2.homeassistant import UnitOfTime
from zigpy.quirks.v2.homeassistant.number import NumberDeviceClass

from zhaquirks.schneiderelectric import (
SE_MANUF_NAME,
SEBasic,
SEOnOff,
SEOnTimeReloadOptions,
SESwitchAction,
SESwitchConfiguration,
SESwitchIndication,
)

BASE_SWITCH = (
QuirkBuilder()
.replaces(SEBasic)
.replaces(SEOnOff)
.number(
attribute_name=SEOnOff.AttributeDefs.se_on_time_reload.name,
cluster_id=SEOnOff.cluster_id,
endpoint_id=1,
min_value=0x0,
max_value=0xFFFFFFFF,
step=1,
unit=UnitOfTime.SECONDS,
device_class=NumberDeviceClass.DURATION,
translation_key="on_time_reload",
fallback_name="On time reload",
)
.number(
attribute_name=SEOnOff.AttributeDefs.se_pre_warning_time.name,
cluster_id=SEOnOff.cluster_id,
endpoint_id=1,
min_value=0x0,
max_value=0xFFFF,
step=1,
unit=UnitOfTime.SECONDS,
device_class=NumberDeviceClass.DURATION,
translation_key="pre_warning_time",
fallback_name="Pre warning time",
)
.enum(
endpoint_id=1,
cluster_id=SEOnOff.cluster_id,
attribute_name=SEOnOff.AttributeDefs.se_on_time_reload_options.name,
enum_class=SEOnTimeReloadOptions,
translation_key="on_time_reload_options",
fallback_name="On time reload options",
)
)

(
BASE_SWITCH.clone()
.applies_to(SE_MANUF_NAME, "NHPB/SWITCH/1")
.applies_to(SE_MANUF_NAME, "CH2AX/SWITCH/1")
.applies_to(SE_MANUF_NAME, "CH10AX/SWITCH/1")
.replaces(SEBasic, endpoint_id=21)
.replaces(SESwitchConfiguration, endpoint_id=21)
.enum(
endpoint_id=21,
cluster_id=SESwitchConfiguration.cluster_id,
attribute_name=SESwitchConfiguration.AttributeDefs.se_switch_indication.name,
enum_class=SESwitchIndication,
translation_key="switch_indication",
fallback_name="Switch indication",
)
.enum(
endpoint_id=21,
cluster_id=SESwitchConfiguration.cluster_id,
attribute_name=SESwitchConfiguration.AttributeDefs.se_switch_actions.name,
enum_class=SESwitchAction,
translation_key="switch_actions",
fallback_name="Switch actions",
)
.add_to_registry()
)

(BASE_SWITCH.clone().applies_to(SE_MANUF_NAME, "PUCK/SWITCH/1").add_to_registry())
Loading