MSA (Multi Scale Automatic) Segmentation Process Description
This process segments a single-cell image by combining multiple different segmentation results. It first computes 42 different cell masks by applying all combinations of segmentation parameters: 3 thresholding algorithms (Minmax, Rosin, Otsu), 7 different sigma values of Gaussian filters for smoothing ranging from 0 to 3 pixels, and 2 different radius parameters for morphological closing. Since it requires only one tuning parameter (either “tightness” or “number of votes”) and “tightness” = 0.5 or “number of votes” = 22 works well for many cases, it achieves almost automatic segmentation.
For more information, please see Noh et al., Cell Systems. 13.6 (2022).
For the explanation of MSA segmentation, please see this document.
This allows you to select which channels you want to segment. By default, all channels will be segmented. Select the channels by clicking on them in the "Available Input Channels" box and then clicking "Select->" to move them to the "Selected Channels" box. You can unselect a channel by clicking the "Delete" button.
Please note, this checkbox is not applicable for the u-probe package. If checked, the segmentation will be applied to the output of the “Generate Summation Channel process”.
Please note, this dropdown menu is not applicable for the u-probe package. If more than one “Generate Summation Channel process” has been run, this allows you to select one from the drop-down menu to use for the MSA segmentation. If choosing “Select later” and more than one process exists, you will be asked at runtime which process to use.
If checked, a slider bar will be available for the user to manually adjust the “tightness” parameter. The “tightness” parameter and the “number of votes” parameter are exclusive options. If “Manually Set Tightness” is checked, the “Manually Set Number of Votes” will be automatically unchecked and the “number of votes” will become “inactive”, and vice versa.
This slider bar allows the user to manually adjust the “tightness” parameter. The default “tightness” = 0.5 works well for most cases. If set to 1, the output is the tightest or smallest masks. If set to 0, the output is the largest masks.
If checked, a slider bar will be available for the user to manually adjust the “number of votes” parameter. The “tightness” parameter and the “number of votes” parameter are exclusive options. If “Manually Set Number of Votes” is checked, the “Manually Set Tightness” will be automatically unchecked and the “tightness” will become “inactive”, and vice versa.
This slider bar allows the user to manually adjust the “number of votes” parameter. The default “number of votes” = 22 works well for most cases. If set to 42, the output is the smallest mask. If set close to 0, the output mask would be larger.
This specifies the number of objects to keep in each mask. That is, if Object Number is set to 2, only the two largest objects in the mask will be kept. This is useful for removing larger background objects or cells which are only partially in the image, while retaining the cell or object of interest.
This parameter specifies the radius of morphological closing for the final refinement.
If checked, the output figures will be displayed during the running of the process.
If checked, verbose mode will be turned on when running the process.
If checked, the result of the segmented image for the selected channel and the specified frame will be displayed in a separate figure. The preview of the segmented image will be automatically updated when other parameters are updated on the setting GUI.
This text box and slider bar allow the user to specify which frame will be displayed for the preview of the segmented image. Please allow time for the preview of the segmented image to be updated when a frame number is changed.
Lyda Hill Department of Bioinformatics and Cecil H. and Ida Green Center for Systems Biology
University of Texas Southwestern Medical Center
Dallas, TX. 75390
Feedback: [email protected]
- u-probe Package Description
- Dark Current Correction Process Description
- Shade Correction Process Description
- Cropping Shade Corrected Movie Process Description
- Segmentation Process Description
- Background Mask Process Description
- Mask Refinement Process Description
- Background Subtraction Process Description
- Transformation Process Description
- Bleedthrough Correction Process Description
- Ratioing Process Description
- Photobleach Correction Process Description
- Ratio Output Process Description