Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
3 changes: 3 additions & 0 deletions docs/release_notes.rst
Original file line number Diff line number Diff line change
Expand Up @@ -16,6 +16,9 @@ Upcoming Release
.. The features listed below are not released yet, but will be part of the next release!
.. To use the features already you have to use the ``master`` branch.

* Corrected units for standing losses of TES technologies from per unit to %/hour and changed parameter names from "Energy losses during storage" to "standing losses" as well as "Temperature difference" to "temperature difference" for naming consistency.


* Add standing losses as parameters for LTES

`v0.13.2 <https://github.com/PyPSA/technology-data/releases/tag/v0.13.2>`__ (13th June 2025)
Expand Down
10 changes: 5 additions & 5 deletions outputs/US/costs_2020.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3721,20 +3721,20 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,,
central water pit storage,Energy losses during storage,0.0078,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
central water pit storage,FOM,0.2354,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,,
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,,
central water pit storage,investment,1.0622,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
central water pit storage,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,,
central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
central water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
central water tank storage,Energy losses during storage,0.0077,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
central water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
central water tank storage,Temperature difference,55.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Typical temperature difference,2020.0,,
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2020.0,,
central water tank storage,investment,3.0361,EUR/kWhCapacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2020.0,,
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2020.0,,
central water tank storage,standing losses,0.0077,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
central water tank storage,temperature difference,55.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Typical temperature difference,2020.0,,
clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0,,
clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0,,
clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,,,
Expand Down Expand Up @@ -3833,14 +3833,14 @@ decentral solar thermal,investment,285719.8393,EUR/1000m2,HP, from old pypsa cos
decentral solar thermal,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0,,
decentral water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
decentral water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
decentral water tank storage,Energy losses during storage,2.1,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
decentral water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
decentral water tank storage,Temperature difference,30.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Typical temperature difference,2020.0,,
decentral water tank storage,VOM,0.7168,EUR/MWh,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Variable O&M,2020.0,,
decentral water tank storage,discount rate,0.04,per unit,Palzer thesis, from old pypsa cost assumptions,2015.0,,
decentral water tank storage,energy to power ratio,0.15,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Ratio between energy storage and input capacity,2020.0,,
decentral water tank storage,investment,419.8622,EUR/kWh,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Specific investment,2020.0,,
decentral water tank storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Technical lifetime,2020.0,,
decentral water tank storage,standing losses,2.1,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
decentral water tank storage,temperature difference,30.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Typical temperature difference,2020.0,,
digestible biomass,fuel,17.0611,EUR/MWh_th,"JRC ENSPRESO ca avg for MINBIOAGRW1, ENS_Ref for 2040",,2010.0,,
digestible biomass to hydrogen,FOM,4.25,%/year,"Zech et.al. DBFZ Report Nr. 19. Hy-NOW - Evaluierung der Verfahren und Technologien für die Bereitstellung von Wasserstoff auf Basis von Biomasse, DBFZ, 2014",,2014.0,,
digestible biomass to hydrogen,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,,,
Expand Down
10 changes: 5 additions & 5 deletions outputs/US/costs_2025.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3801,20 +3801,20 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,,
central water pit storage,Energy losses during storage,0.0078,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
central water pit storage,FOM,0.2354,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,,
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,,
central water pit storage,investment,1.0622,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,,
central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
central water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
central water tank storage,Energy losses during storage,0.0077,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
central water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
central water tank storage,Temperature difference,55.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Typical temperature difference,2020.0,,
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2020.0,,
central water tank storage,investment,3.0361,EUR/kWhCapacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2020.0,,
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2020.0,,
central water tank storage,standing losses,0.0077,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
central water tank storage,temperature difference,55.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Typical temperature difference,2020.0,,
clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0,,
clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0,,
clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,,,
Expand Down Expand Up @@ -3919,14 +3919,14 @@ decentral solar thermal,investment,285719.8393,EUR/1000m2,HP, from old pypsa cos
decentral solar thermal,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0,,
decentral water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
decentral water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
decentral water tank storage,Energy losses during storage,2.1,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
decentral water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
decentral water tank storage,Temperature difference,30.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Typical temperature difference,2020.0,,
decentral water tank storage,VOM,0.8704,EUR/MWh,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Variable O&M,2020.0,,
decentral water tank storage,discount rate,0.04,per unit,Palzer thesis, from old pypsa cost assumptions,2015.0,,
decentral water tank storage,energy to power ratio,0.15,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Ratio between energy storage and input capacity,2020.0,,
decentral water tank storage,investment,419.8622,EUR/kWh,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Specific investment,2020.0,,
decentral water tank storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Technical lifetime,2020.0,,
decentral water tank storage,standing losses,2.1,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
decentral water tank storage,temperature difference,30.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Typical temperature difference,2020.0,,
digestible biomass,fuel,17.0611,EUR/MWh_th,"JRC ENSPRESO ca avg for MINBIOAGRW1, ENS_Ref for 2040",,2010.0,,
digestible biomass to hydrogen,FOM,4.25,%/year,"Zech et.al. DBFZ Report Nr. 19. Hy-NOW - Evaluierung der Verfahren und Technologien für die Bereitstellung von Wasserstoff auf Basis von Biomasse, DBFZ, 2014",,2014.0,,
digestible biomass to hydrogen,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,,,
Expand Down
Loading