Safety mechanisms

Events

There are four levels of event severity:

  • INFO
  • WARNING
  • CRITICAL
  • FATAL

INFO events are informational, and don't indicate a problem.

WARNING events indicate a potential problem which is not yet serious.

CRITICAL events signal imminent contactor opening and escalate to FATAL after a timeout (which differs by event type). To catch intermittent (flapping) faults, a cumulative time buffer increments while the event is active and decrements when cleared; if the buffer fills, the event escalates to FATAL.

FATAL events immediately trigger the contactor opening sequence, and require manual intervention to reset. Unlike the other event types, FATAL events do not clear when the triggering condition stops.

Current limits

The BMS continuously calculates the maximum allowed charge and discharge current in its present state, and these limits are transmitted to the inverter.

The limits are the lesser of several different calculations:

Temperature derating, which linearly tapers the maximum current such that it reaches zero at the maximum temperature limit. The limits are different for charging and discharging, according to the cell chemistry.

State of charge derating

Cell voltage

There are two sets of cell voltage limits - hard limits and soft limits.

If the hard limits (the most extreme) are exceeded, a FATAL event is raised and the contactors quickly open to prevent overcharge/overdischarge. This state will require manual restoration of the battery before the BMS can be successfully reset without immediately tripping again.

The soft limits allow for a more graceful recovery. In the soft-limit region, the battery can still be charged (in the case of the lower limit) or discharged (in the case of the upper limit) at a reduced current. If however the overcharge or overdischarge continues beyond a certain threshold (measured in amp-hours), or the voltage stays in the soft-limit region for more than an hour, a FATAL event will be raised and the contactors will open.

This ensures that an unattended battery that overcharges or overdischarges will be automatically disconnected whilst it is still in the soft-limit region, and can then be safely discharged/charged back into normal service after manual intervention.

Response time

The main loop of the BMS runs every 20 milliseconds. It will therefore take at least 20ms for the BMS to react to a change, up to several multiples of 20ms if the signal propagates through the model in stages.

Most operations performed in the main loop should easily complete within the 20ms deadline. However the BMS performs occasional flash memory writes which can take much longer (the worst case block-erase time of the SPI flash chip is 2 seconds). The normal WARNING that occurs if a loop tick overruns is suppressed when flash memory operations are performed.

A system-wide watchdog timer is set up with a 5 second deadline, which gets reset every tick. If the main loop stalls for more than 5 seconds, the chip will reboot and raise a WARNING event.