MQTT Topic Reference

Docs: Getting Started | Configuration | API Reference | Architecture | MQTT Topics | SNMP OIDs | Multi-PDU | Security | Troubleshooting | Features

Complete reference for every MQTT topic the bridge publishes and consumes. {device} is the device ID — auto-assigned as pdu-01, pdu-02, etc. or set manually. Outlet numbers ({n}) and bank numbers are 1-indexed.


Quick Start

# See all topics in real time
mosquitto_sub -t 'pdu/#' -v

# Turn off outlet 3 on first PDU
mosquitto_pub -t 'pdu/pdu-01/outlet/3/command' -m 'off'

Topic Tree

graph TD
    Root["pdu/{device}"]

    Root --> Status["status"]
    Root --> Device["device"]
    Root --> Input["input/"]
    Root --> Outlet["outlet/{n}/"]
    Root --> Bank["bank/{n}/"]
    Root --> ATS["ats/"]
    Root --> Source["source/{a,b}/"]
    Root --> Total["total/"]
    Root --> Coldstart["coldstart/"]
    Root --> Env["environment/"]
    Root --> BridgeMeta["bridge/"]
    Root --> Auto["automation/"]

    Input --> IV["voltage"]
    Input --> IF["frequency"]

    Outlet --> OS["state"]
    Outlet --> ON["name"]
    Outlet --> OC["current"]
    Outlet --> OP["power"]
    Outlet --> OE["energy"]
    Outlet --> CMD["command"]
    CMD --> RESP["response"]

    Bank --> BC["current"]
    Bank --> BV["voltage"]
    Bank --> BP["power"]
    Bank --> BA["apparent_power"]
    Bank --> BPF["power_factor"]
    Bank --> BEn["energy"]
    Bank --> BLS["load_state"]

    ATS --> ATSpref["preferred_source"]
    ATS --> ATScur["current_source"]
    ATS --> ATSauto["auto_transfer"]
    ATS --> ATSred["redundancy"]
    ATS --> ATSvs["voltage_sensitivity"]
    ATS --> ATStv["transfer_voltage"]
    ATS --> ATSul["voltage_upper_limit"]
    ATS --> ATSll["voltage_lower_limit"]

    Source --> SV["voltage"]
    Source --> SF["frequency"]
    Source --> SVS["voltage_status"]

    Total --> TL["load"]
    Total --> TP["power"]
    Total --> TE["energy"]

    Coldstart --> CD["delay"]
    Coldstart --> CS["state"]

    Env --> ET["temperature"]
    Env --> EH["humidity"]
    Env --> EC["contact/{n}"]

    BridgeMeta --> BS["status"]

    Auto --> AStatus["status"]
    Auto --> AEvent["event"]

    style Root fill:#1a1a2e,stroke:#0ea5e9,color:#e2e4e9
    style Status fill:#1a1a2e,stroke:#00dc82,color:#e2e4e9
    style Device fill:#1a1a2e,stroke:#00dc82,color:#e2e4e9
    style Input fill:#1a1a2e,stroke:#00dc82,color:#e2e4e9
    style Outlet fill:#1a1a2e,stroke:#00dc82,color:#e2e4e9
    style Bank fill:#1a1a2e,stroke:#00dc82,color:#e2e4e9
    style ATS fill:#1a1a2e,stroke:#00dc82,color:#e2e4e9
    style Source fill:#1a1a2e,stroke:#00dc82,color:#e2e4e9
    style Total fill:#1a1a2e,stroke:#00dc82,color:#e2e4e9
    style Coldstart fill:#1a1a2e,stroke:#00dc82,color:#e2e4e9
    style Env fill:#1a1a2e,stroke:#00dc82,color:#e2e4e9
    style BridgeMeta fill:#1a1a2e,stroke:#64748b,color:#e2e4e9
    style Auto fill:#1a1a2e,stroke:#ec4899,color:#e2e4e9
    style CMD fill:#1a1a2e,stroke:#f59e0b,color:#e2e4e9
    style RESP fill:#1a1a2e,stroke:#f59e0b,color:#e2e4e9
Loading

Legend: Green = status (bridge publishes, you subscribe). Yellow = commands (you publish, bridge subscribes). Pink = automation. Gray = bridge health.


Status Summary

Topic Payload Rate
pdu/{device}/status JSON ~1 Hz, retained

Contains device_name, outlet_count, phase_count, input_voltage, input_frequency, timestamp, and an identity object (serial, model, firmware) when available.


Device Info

Topic Payload Rate
pdu/{device}/device JSON ~30 s, retained

Low-rate publish of everything the bridge knows about the hardware:

{
  "device_id": "pdu-01",
  "serial": "ABCD1234",
  "serial_numeric": "12345678",
  "model": "PDU44001",
  "name": "CyberPower PDU",
  "firmware_main": "01.01.01",
  "firmware_secondary": "01.01.01",
  "hardware_rev": 3,
  "outlet_count": 10,
  "phase_count": 1,
  "max_current": 30.0,
  "transport": "snmp",
  "state": "healthy",
  "sys_name": "PDU-Rack1",
  "sys_location": "Server Room A",
  "sys_contact": "admin@example.com",
  "timestamp": 1708531200.0
}

Input Power

Topic Payload Description
pdu/{device}/input/voltage float Input voltage (V)
pdu/{device}/input/frequency float Input frequency (Hz)

Per-Outlet

Replace {n} with outlet number (1-indexed).

Topic Payload Description
pdu/{device}/outlet/{n}/state on / off Relay state
pdu/{device}/outlet/{n}/name string Outlet display name
pdu/{device}/outlet/{n}/current float Current (A) — metered models only
pdu/{device}/outlet/{n}/power float Power (W) — metered models only
pdu/{device}/outlet/{n}/energy float Energy (kWh) — metered models only

Per-Bank

Replace {n} with bank number (1-indexed).

Topic Payload Description
pdu/{device}/bank/{n}/current float Bank current (A)
pdu/{device}/bank/{n}/voltage float Bank voltage (V)
pdu/{device}/bank/{n}/power float Active power (W)
pdu/{device}/bank/{n}/apparent_power float Apparent power (VA)
pdu/{device}/bank/{n}/power_factor float Power factor (0–1)
pdu/{device}/bank/{n}/energy float Cumulative energy (kWh) — if supported
pdu/{device}/bank/{n}/last_update string Timestamp of last reading — if supported
pdu/{device}/bank/{n}/load_state string normal, low, nearOverload, overload

ATS (Transfer Switch)

Published only on ATS-capable models. The bridge auto-detects ATS support.

ATS Status

Topic Payload Description
pdu/{device}/ats/preferred_source A / B Configured preferred input source
pdu/{device}/ats/current_source A / B Which input is currently active
pdu/{device}/ats/auto_transfer on / off Automatic transfer enabled
pdu/{device}/ats/redundancy ok / lost Dual-source redundancy status

ATS Configuration

Topic Payload Description
pdu/{device}/ats/voltage_sensitivity string Normal, High, or Low
pdu/{device}/ats/transfer_voltage float Transfer trigger voltage (V)
pdu/{device}/ats/voltage_upper_limit float Upper voltage limit (V)
pdu/{device}/ats/voltage_lower_limit float Lower voltage limit (V)

Per-Source (ATS Models)

Individual readings for each power input. Replace {s} with a or b.

Topic Payload Description
pdu/{device}/source/{s}/voltage float Source voltage (V)
pdu/{device}/source/{s}/frequency float Source frequency (Hz)
pdu/{device}/source/{s}/voltage_status string normal, overVoltage, underVoltage

Totals

Aggregate readings across all outlets/banks.

Topic Payload Description
pdu/{device}/total/load float Total load (A)
pdu/{device}/total/power float Total power (W)
pdu/{device}/total/energy float Total energy (kWh)

Coldstart

Topic Payload Description
pdu/{device}/coldstart/delay int Seconds to wait after power restore
pdu/{device}/coldstart/state string allon or prevstate

Environment

Published only when an ENVIROSENSOR probe is connected. The bridge probes for the sensor gracefully — no errors if absent.

Topic Payload Description
pdu/{device}/environment/temperature float Temperature (degrees)
pdu/{device}/environment/humidity float Humidity (%)
pdu/{device}/environment/contact/{n} open / closed Dry contact sensors (1–4)

Commands

Publish to these topics to control outlets.

Topic Payload Description
pdu/{device}/outlet/{n}/command on Turn outlet on
off Turn outlet off
reboot Power-cycle outlet
delayon Delayed power on (uses PDU-configured delay)
delayoff Delayed power off
cancel Cancel pending delayed command
pdu/{device}/outlet/{n}/command/response JSON Result published by bridge after command

Command Response

{
  "success": true,
  "command": "off",
  "outlet": 3,
  "error": null,
  "ts": 1708531200.0
}

Automation

Topic Payload Description
pdu/{device}/automation/status JSON array All rule states (name, active, last trigger, etc.)
pdu/{device}/automation/event JSON Published when a rule fires (QoS 1, not retained)

Bridge Health

Topic Payload Description
pdu/{device}/bridge/status online / offline Set to online on connect. The broker publishes offline via LWT if the bridge disconnects unexpectedly.

Home Assistant Auto-Discovery

The bridge publishes HA MQTT Discovery configs to homeassistant/switch/… and homeassistant/sensor/… on first poll. This creates entities automatically in Home Assistant for:

  • Outlet switches (on/off/reboot)
  • Bank sensors (voltage, current, power, apparent power, power factor, energy, load state)
  • Input sensors (voltage, frequency)
  • ATS sensors (all 8 config + status topics)
  • Source A/B sensors (voltage, frequency, status)
  • Coldstart sensors (delay, state)
  • Total sensors (load, power, energy)
  • Environment sensors (temperature, humidity)
  • Bridge connectivity binary sensor

When device identity is available (serial number from SNMP), HA uses it for stable unique IDs that survive device ID renames.


Notes

  • All status topics are retained. Subscribers get the latest value immediately on connect.
  • Conditional topics. ATS, source, environment, coldstart, per-outlet metering, and bank energy topics only appear when the hardware supports them. The bridge never publishes empty/zero placeholders.
  • Metering floor correction. The PDU reports phantom readings (1W, 0.2A) for idle outlets. The bridge zeroes these out automatically.
  • Multi-PDU. Each PDU gets its own {device} prefix. Subscribe to pdu/# to see all devices, or pdu/pdu-01/# for one.

See also: Architecture | SNMP OIDs | Configuration