Multi-PDU Setup

Docs: Getting Started | Configuration | API Reference | Architecture | MQTT Topics | SNMP OIDs | Multi-PDU | Security | Troubleshooting | Features

The bridge can monitor multiple CyberPower PDUs from a single instance. Each PDU gets its own SNMP poller, automation engine, outlet name overrides, and MQTT topic namespace -- all running concurrently in the same bridge container.


When You Need Multi-PDU

You should use multi-PDU mode if you have:

  • Multiple PDUs in the same rack or across racks
  • A primary and backup PDU
  • PDUs on different subnets that a single bridge can reach
  • A centralized monitoring dashboard for your entire power infrastructure

If you only have one PDU, the default single-PDU mode (configured via .env) is simpler and works perfectly.


How It Works

graph TB
    subgraph Bridge ["Python Bridge Container"]
        Manager["BridgeManager<br/><small>shared MQTT, history, web</small>"]
        Poller1["PDUPoller #1<br/><small>SNMP to rack1-pdu</small>"]
        Poller2["PDUPoller #2<br/><small>SNMP to rack2-pdu</small>"]
        Poller3["PDUPoller #3<br/><small>SNMP to rack3-pdu</small>"]
    end

    PDU1["PDU @ 192.168.20.177"]
    PDU2["PDU @ 192.168.20.178"]
    PDU3["PDU @ 192.168.20.179"]

    Manager --> Poller1
    Manager --> Poller2
    Manager --> Poller3
    Poller1 <-->|SNMP| PDU1
    Poller2 <-->|SNMP| PDU2
    Poller3 <-->|SNMP| PDU3

    style Bridge fill:#0f172a,stroke:#475569,color:#f8fafc
    style Manager fill:#1a1a2e,stroke:#0ea5e9,color:#e2e4e9
    style Poller1 fill:#1a1a2e,stroke:#10b981,color:#e2e4e9
    style Poller2 fill:#1a1a2e,stroke:#10b981,color:#e2e4e9
    style Poller3 fill:#1a1a2e,stroke:#10b981,color:#e2e4e9
    style PDU1 fill:#1a1a2e,stroke:#f59e0b,color:#e2e4e9
    style PDU2 fill:#1a1a2e,stroke:#f59e0b,color:#e2e4e9
    style PDU3 fill:#1a1a2e,stroke:#f59e0b,color:#e2e4e9
Loading

The BridgeManager is the top-level orchestrator. It creates shared services (MQTT connection, SQLite history database, web server) and then launches one PDUPoller per configured PDU as concurrent asyncio tasks. Pollers are staggered by 100ms at startup to avoid SNMP congestion.

Each poller independently:

  • Discovers the PDU's identity (model, serial, outlet count) via SNMP
  • Auto-detects the bank count
  • Runs its own 1Hz poll loop
  • Evaluates its own automation rules (stored in /data/rules_{device_id}.json)
  • Manages its own outlet name overrides (stored in /data/outlet_names_{device_id}.json)

All pollers share the same MQTT connection, history database (with a device_id column), and web server.


pdus.json Format

Create a pdus.json file to configure your PDUs. The file is stored at the path specified by BRIDGE_PDUS_FILE (default: /data/pdus.json inside the container).

{
  "pdus": [
    {
      "device_id": "rack1-pdu",
      "host": "192.168.20.177",
      "snmp_port": 161,
      "community_read": "public",
      "community_write": "private",
      "label": "Main Rack PDU",
      "enabled": true,
      "num_banks": 2
    },
    {
      "device_id": "rack2-pdu",
      "host": "192.168.20.178",
      "label": "Secondary Rack PDU"
    },
    {
      "device_id": "old-pdu",
      "host": "192.168.20.179",
      "label": "Decommissioned",
      "enabled": false
    }
  ]
}

Field reference

Field Required Default Description
device_id Yes -- Unique ID used in MQTT topics (pdu/{device_id}/...) and API queries. Must not contain / # + or spaces.
host Yes -- IP address or hostname of the PDU
snmp_port No 161 SNMP port
community_read No public SNMP v2c read community string
community_write No private SNMP v2c write community string
label No "" Human-friendly display name for the web UI
enabled No true Set to false to skip this PDU without removing it from the file
num_banks No 2 Default bank count hint (auto-detected from SNMP at startup)
serial_port No "" Serial device path (e.g., /dev/ttyUSB0) for management access
serial_baud No 9600 Serial baud rate
serial_username No "cyber" Serial console login username
serial_password No "cyber" Serial console login password
transport No "snmp" Primary transport: "snmp", "serial", or "both"

Configuration priority

The bridge loads PDU configuration in this order:

  1. pdus.json -- If the file exists and contains valid PDU entries, it is used exclusively. The .env single-PDU variables (PDU_HOST, etc.) are ignored.
  2. Environment variables -- If pdus.json does not exist, the bridge falls back to the single-PDU settings from .env.
  3. Mock mode -- If BRIDGE_MOCK_MODE=true and no other config is found, a simulated PDU is created.

Using the Wizard

The interactive wizard walks you through discovering and configuring PDUs:

./wizard

The wizard:

  1. Scans your network for CyberPower PDUs via SNMP
  2. Lets you select which PDUs to monitor
  3. Tests SNMP connectivity to each selected PDU
  4. Writes the pdus.json configuration file
  5. Prints next steps to get running

The wizard runs inside the Docker container (if the stack is running) or natively if pysnmp-lextudio is installed.


Using the Scanner

The scanner discovers CyberPower PDUs on your network without the interactive wizard:

# Auto-detect subnet and scan
./scan

# Scan a specific subnet
./scan --subnet 192.168.20.0/24

# Scan with a non-default community string
./scan --subnet 10.0.0.0/24 --community my-community

# Adjust timeout per host
./scan --timeout 2

The scanner queries each IP for the CyberPower ePDU MIB and prints a table of discovered devices with model, serial number, and outlet count.


Docker Compose for Multiple PDUs

No changes to docker-compose.yml are needed for multi-PDU mode. All PDUs are handled by the same bridge container. The only requirement is that the bridge container can reach all PDU IP addresses over the network.

Since the bridge uses network_mode: host, it has direct access to the host network and can reach PDUs on any subnet the host can reach.

If you need PDUs on different VLANs or subnets, make sure routing is configured on the host machine.


API Endpoints for PDU Management

You can manage PDUs at runtime through the REST API without editing pdus.json manually.

List all PDUs

curl http://localhost:8080/api/pdus

Add a new PDU

curl -X POST http://localhost:8080/api/pdus \
  -H 'Content-Type: application/json' \
  -d '{
    "device_id": "rack3-pdu",
    "host": "192.168.20.179",
    "label": "Third Rack"
  }'

Update a PDU

curl -X PUT http://localhost:8080/api/pdus/rack3-pdu \
  -H 'Content-Type: application/json' \
  -d '{
    "device_id": "rack3-pdu",
    "host": "192.168.20.179",
    "label": "Updated Label",
    "community_read": "new-community"
  }'

Remove a PDU

curl -X DELETE http://localhost:8080/api/pdus/rack3-pdu

Discover PDUs on the network

curl -X POST http://localhost:8080/api/pdus/discover

Changes made through the API are persisted to pdus.json automatically.

Note: Adding or removing PDUs through the API updates the configuration file, but new pollers are not started until the bridge is restarted. To start polling a newly added PDU, restart the bridge: ./start --restart.


MQTT Topic Namespacing

Each PDU gets its own namespace in the MQTT topic hierarchy:

pdu/rack1-pdu/status              # Full status JSON for rack1-pdu
pdu/rack1-pdu/outlet/1/state      # Outlet 1 state on rack1-pdu
pdu/rack1-pdu/bank/1/power        # Bank 1 power on rack1-pdu

pdu/rack2-pdu/status              # Full status JSON for rack2-pdu
pdu/rack2-pdu/outlet/1/state      # Outlet 1 state on rack2-pdu
pdu/rack2-pdu/bank/1/power        # Bank 1 power on rack2-pdu

Subscribe to all PDUs at once:

mosquitto_sub -t 'pdu/#' -v

Subscribe to a specific PDU:

mosquitto_sub -t 'pdu/rack1-pdu/#' -v

Commands also use the device namespace:

# Turn off outlet 3 on rack2-pdu
mosquitto_pub -t 'pdu/rack2-pdu/outlet/3/command' -m 'off'

Web UI Device Selector

When multiple PDUs are registered, the web dashboard shows a device selector in the header. Select a PDU to view its status, outlets, charts, and automation rules.

The API endpoints accept ?device_id= to filter by device:

# Get status for a specific PDU
curl http://localhost:8080/api/status?device_id=rack2-pdu

# Get bank history for a specific PDU
curl http://localhost:8080/api/history/banks?range=1h&device_id=rack1-pdu

# List automation rules for a specific PDU
curl http://localhost:8080/api/rules?device_id=rack1-pdu

Home Assistant with Multiple PDUs

Each PDU appears as a separate device in Home Assistant. MQTT Discovery configurations are published per-device, so you get:

  • Separate outlet switches for each PDU
  • Separate bank sensors for each PDU
  • Separate bridge status sensors for each PDU

Devices are named CyberPower {DEVICE_ID} (e.g., CyberPower RACK1-PDU).


Per-Device Data Storage

In multi-PDU mode, each PDU gets its own:

Data Single-PDU Path Multi-PDU Path
Automation rules /data/rules.json /data/rules_{device_id}.json
Outlet names /data/outlet_names.json /data/outlet_names_{device_id}.json
History Shared history.db with device_id='' Shared history.db with device_id column
Energy rollups Shared energy_daily / energy_monthly tables with device_id column
PDF reports {device_id}_weekly_{date}.pdf and {device_id}_monthly_{month}.pdf per device