Skip to content

spec get device linx max baud

Ken Sharp edited this page Dec 10, 2025 · 2 revisions

Get Device LINX Max Baud Rate

Get the maximum baud rate the LINX device is capable of using to communicate with the host.

LabVIEW

Developer Note

N/A

Command Packet

Get Device LINX Max Baud Rate
Description Get the maximum baud rate the LINX device is capable of using to communicate with the host.
Size 7 Bytes
Format 0 1 2 3 4 5 6
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
SoF : 0xFF PACKET SIZE : 0x07 PACKET NUM CMD : 0x0023 CHECKSUM
SoF Start of Frame. Always 0xFF.
PACKET SIZE Packet Size In Bytes
PACKET NUM The Current Packet Number. This value increments with each new packet or repeats for a multi packet command.
CMD Get Device LINX Max Baud Rate Command.
CHECKSUM Checksum. Computed by adding all of the bytes in the packet in U8 form ignoring rollover.

LINX Target

Developer Note

N/A

Response Packet

Get Device LINX Max Baud Rate Response
Description LINX device's response to Get Device LINX Max Baud Rate Command
Size 10 Bytes
Format 0 1 2 3 4 5 6 7 8 9
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
SoF : 0xFF PACKET SIZE : 0x0A PACKET NUM STATUS Baud Rate CHECKSUM
SoF Start of Frame. Always 0xFF.
PACKET SIZE Total packet size in bytes.
PACKET NUM The packet number of the packet that generated the response.
STATUS See Return Status section below.
Baud Rate Baud Rate MSB First (U32)
CHECKSUM Checksum. Computed by adding all of the bytes in the packet in U8 form ignoring rollover.

Return Status

No function specific statuses. See Return Status for universal return statuses.

Related Links

LINX

Clone this wiki locally