Skip to content

spec system get max baud rate

Ken Sharp edited this page Dec 10, 2025 · 2 revisions

Get Max Baud Rate

Get the maximum serial baud rate supported by the LINX device.

LabVIEW

Developer Note

This will be used to auto negotiate the baud rate

Command Packet

Get Max Baud Rate
Description Get the maximum serial baud rate supported by the LINX device.
Size 7 Bytes
Format 0 1 2 3 4 5 6
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
SoF : 0xFF PACKET SIZE : 0x07 PACKET NUM CMD : 0x0005 CHECKSUM
SoF Start of Frame. Always 0xFF.
PACKET SIZE Packet Size In Bytes
PACKET NUM The Current Packet Number. This value increments with each new packet.
CMD Flush Command.
CHECKSUM Checksum. Computed by adding all of the bytes in the packet in U8 form ignoring rollover.

LINX Target

Developer Note

Return the maximum serial baud rate supported by the device.

Response Packet

Get Max Baud Rate Response
Description LINX device's response to the Get Max Baud Rate command
Size 6 Bytes
Format 0 1 2 3 4 5 6 7 8 9
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
SoF : 0xFF PACKET SIZE : 0x0A PACKET NUM STATUS BAUD RATE CHECKSUM
SoF Start of Frame. Always 0xFF.
PACKET SIZE Total packet size in bytes.
PACKET NUM The packet number of the packet that generated the response.
STATUS See Return Status section below.
BAUD RATE Maximum baud rate supported by the LINX device (U32)
CHECKSUM Checksum. Computed by adding all of the bytes in the packet in U8 form ignoring rollover.

Return Status

No function specific statuses. See Return Status for universal return statuses.